Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5999-00-236-0320 Item Description: Shielding Gasket El | 5999 | 002360320 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | U | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
018-0150-010 | 6 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAGR | CROSS-SECTIONAL SHAPE STYLE | MESH AND COMPOSITION |
AAUB | HOLE DIAMETER | 0.187 INCHES NOMINAL |
ABHP | OVERALL LENGTH | 14.500 INCHES NOMINAL |
ABJH | III TEMP RATING | -40.0 DEG CELSIUS AND 75.0 DEG CELSIUS |
ABMK | OVERALL WIDTH | 6.437 INCHES NOMINAL |
ABNH | MINOR WIDTH | 0.125 INCHES MINIMUM AND 0.156 INCHES MAXIMUM |
ADPW | OUTSIDE CORNER RADIUS | 0.125 INCHES NOMINAL |
ADUE | APERTURE WIDTH | 5.438 INCHES NOMINAL |
ADUF | APERTURE LENGTH | 13.500 INCHES NOMINAL |
ADUY | CENTER TO CENTER DISTANCE BETWEEN BOLT HOLES ALONG WIDTH | 3.500 INCHES NOMINAL |
ADUZ | CENTER TO CENTER DISTANCE BETWEEN BOLT HOLES ALONG LENGTH | 3.300 INCHES NOMINAL |
ADVD | OUTSIDE EDGE TO BOLT HOLE CENTER DISTANCE ALONG WIDTH | 0.219 INCHES NOMINAL |
ADVE | OUTSIDE EDGE TO BOLT HOLE CENTER DISTANCE ALONG LENGTH | 0.219 INCHES NOMINAL |
ADVN | CROSS-SECTIONAL HEIGHT | 0.046 INCHES MINIMUM AND 0.091 INCHES MAXIMUM |
ADWK | MINOR HEIGHT | 0.062 INCHES MINIMUM AND 0.078 INCHES MAXIMUM |
AECS | BOLT HOLE QUANTITY | 12 |
CTNJ | ENVIRONMENTAL PROTECTION MATERIAL LOCATION | AROUND RF SHIELDING GASKET OUTER PERIMETER |
MATT | MATERIAL | ALUMINUM ALLOY 5056 EMI/RFI CONDUCTOR |
MATT | MATERIAL | RUBBER CHLOROPRENE CLASS CR ENVIRONMENTAL SEAL |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | AMS 4182,CLASS A,ALLOY 5056 ASSN STD SINGLE MATERIAL RESPONSE EMI/RFI CONDUCTOR |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | MIL-R-6130,TYPE 2,GRADE A,CONDITION MEDIUM MIL SPEC SINGLE MATERIAL RESPONSE ENVIRONMENTAL SEAL |
STYL | STYLE DESIGNATOR | NON-CIRCULAR |
018-0005-02 | 018-0005-03 | 018-0005-01 | 018-000025 |
018-0005-01 | 018-000029 | 018-0005-3 | 018-0005-02 |
018-000006 | 018-0001 | 018-00008-01 | 018-0005-03 |
018-000025 | 018-0005-02 | 018-000025 | 018-0005-01 |