MRC | Criteria | Characteristic |
---|---|---|
TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 0.500 INCHES NOMINAL |
AEHZ | MAXIMUM OPERATING TEMP | 100.0 DEG CELSIUS |
AEJH | PROBE DIAMETER | 0.500 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | ENCASED |
CQWD | ZERO POWER RESISTANCE | 2.252 KILOHMS |
FEAT | SPECIAL FEATURES | CABLE TERMINATION IS PHONE PLUG; 10 FT (3 M) LONG VINYL JACKETED CABLE; PLASTIC CAGE PROVIDES PROTECTION FOR THERMISTOR SENSOR WHILE LEAVING IT OPEN TO THE AIR FLOW |
ABHP | OVERALL LENGTH | 120.000 INCHES NOMINAL |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 70.0 DEG CELSIUS |
AEJG | PROBE LENGTH | 1.500 INCHES NOMINAL |
CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | PRECISION THEREMISTOR SENSOR FOR AIR TEMPERATURE MEASURES |
ON-2466 | ON 388 ALM | ON-420-0338 | ON-420-0270 |
ON-389 ALM | ON-390 ALM | ON-323 U | ON-389 ALM |
ON-323 U | ON-175 | ON-175 | ON-175 |
ON-388 ALM | ON-420-0270 | ON-175 | ON-390 ALM |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.