Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-469-2482 Item Description: Circuit Breaker | 5925 | 014692482 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
45-700-Ig1-S10-5a | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AGAV | III END ITEM IDENTIFICATION | FORCE PROVIDER (USED ON: 4120-01-413-7835) |
ADAQ | BODY LENGTH | 1.140 INCHES NOMINAL |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 SINGLE LOCATION |
THSD | THREAD SERIES DESIGNATOR | UNS |
CPRQ | RESET METHOD | MANUAL |
TTQY | TERMINAL TYPE AND QUANTITY | 2 SCREW |
ABXD | BUSHING LENGTH | 0.400 INCHES NOMINAL |
AKPX | POLE QUANTITY | 1 |
ADAT | BODY WIDTH | 0.570 INCHES NOMINAL |
FREQ | FREQUENCY IN HERTZ | 60.0 SINGLE LOCATION |
CMLP | THREAD QUANTITY PER INCH | 27 |
FEAT | SPECIAL FEATURES | THIS ITEM HAS A NEW FEATURE: ON/OFF SWITCH BUILDED WITHIN THE CIRCUIT BREAKER // SPECIFICATIONS: A. MAX VOLTAGE RATINGS(250 VAC & 28 VDC) X B. MAX INTERRUPTING CAPACITY(< 2000 AMP) X C. DIELECTRIC STRENGTH(1500 VAC) X D. INSULATION RESISTANCE(100 MEGOHM) X E. LIFE(6000 CYCLES AT RATED CURRENT) X F. CURRENT RATING(5 AMP) X G. TEMPERATURE RANGE(-40 DEG.F TO 160 DEG.F) |
ADTV | CASE MATERIAL | PLASTIC |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 5.0 AMPERES AC AND 5.0 AMPERES DC SINGLE LOCATION |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING |
CQJX | NOMINAL THREAD SIZE | 0.375 INCHES |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC AND 28.0 DC SINGLE LOCATION |
BBRG | III STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH BUTTON |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 10.000 MINIMUM AT 200 PCT AND 40.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
AAQL | BODY STYLE | SINGLE POLE TYPE |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 2000.0 AC AND 2000.0 DC SINGLE LOCATION |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 40.0 DEG CELSIUS NOMINAL SINGLE LOCATION |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.780 INCHES NOMINAL |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | DUSTPROOF AND FUNGUS RESISTANT |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.220 INCHES NOMINAL |
CPRJ | TRIP RELEASE METHOD | THERMAL SINGLE LOCATION |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote