Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-353-1386 Item Description: Circuit Breaker | 5925 | 013531386 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
300461-007 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | SINGLE POLE TYPE |
ADAQ | BODY LENGTH | 1.220 INCHES NOMINAL |
ADAT | BODY WIDTH | 0.710 INCHES NOMINAL |
ADTV | CASE MATERIAL | METAL |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.930 INCHES NOMINAL |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING W/PANEL SEAL |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 7.5 AC SINGLE LOCATION AND 7.5 DC SINGLE LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
CPRJ | TRIP RELEASE METHOD | MAGNETIC SINGLE LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 SINGLE LOCATION |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH-PULL |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
CQJX | NOMINAL THREAD SIZE | 0.472 INCHES |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 5.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 15.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
FREQ | FREQUENCY IN HERTZ | 60.0 SINGLE LOCATION |
TTQY | TERMINAL TYPE AND QUANTITY | 2 TAB W/SCREW |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 115.0 AMPERES AC SINGLE LOCATION AND 28.0 AMPERES DC SINGLE LOCATION |
THSD | THREAD SERIES DESIGNATOR | UNC |
ABXD | BUSHING LENGTH | 0.260 INCHES NOMINAL |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.730 INCHES MAXIMUM |
AKPX | POLE QUANTITY | 1 |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 3500.0 AC SINGLE LOCATION AND 6000.0 DC SINGLE LOCATION |
CPRQ | RESET METHOD | MANUAL |
300-00-102J | 300-00-2K | 300-00-153J | 300-00-153J |
300-00-10K | 300-00-200 | 300-00-2K | 300-00 |
300-00-102J | 300-0-80X7-32 | 300-0-032768-52031 | 300-0-032768 |
300-00-1.5K | 300 00 2 5K | 300-0-80X7-32 | 300-00 |