5945-01-327-0952 Item Description: Relay Electromagnet | 5945 | 013270952 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | C | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Az820-2c-24de | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 0.775 INCHES MINIMUM AND 0.799 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 0.500 INCHES MINIMUM AND 0.548 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 0.378 INCHES MINIMUM AND 0.402 INCHES MAXIMUM |
ADZC | ENVIRONMENTAL PROTECTION | SHOCK RESISTANT AND VIBRATION RESISTANT |
AFRG | CONTACT MATERIAL | GOLD AND SILVER |
AGAV | END ITEM IDENTIFICATION | 5895-01-167-2479 AN/FSC-92(V),SWITCHING SYSTE |
AKDX | WINDING QUANTITY | 1 |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
APCN | COIL QUANTITY | 1 |
APNA | WINDING DC RESISTANCE RATING | 1.4 KILOHMS NOMINAL SINGLE WINDING |
APNP | DUTY TYPE | CONTINUOUS |
CBME | III CUBIC MEASURE | 0.160 CUBIC INCHES |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CRXH | TIME DELAY | 0.002 SECONDS NOMINAL FIXED RELEASE TIME |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 24.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 3.0 AMPERES AC RESISTIVE LOAD AND 3.0 AMPERES DC RESISTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 250.0 AC AND 220.0 DC |
PRMT | PRECIOUS MATERIAL | GOLD AND SILVER |
ZZZK | SPECIFICATION/STANDARD DATA | 25512-450015 MANUFACTURERS SPECIFICATION CONTROL |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CBBL | FEATURES PROVIDED | POLARIZED |
PMLC | PRECIOUS MATERIAL AND LOCATION | CONTACTS GOLD AND CONTACTS SILVER |
TTQY | TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |
APNQ | ARC QUENCHING METHOD | AIR |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
CRXH | TIME DELAY | 0.003 SECONDS NOMINAL FIXED OPERATE TIME |
AZ8-1AT-5DE | AZ8-1AT-48D | AZ8-1AT-24DE | AZ8-1AH-12DEF |
AZ8-1AT-6D | AZ8-1AT-48DE | AZ8-1AT-12DF | AZ8-1AT-48DH |
AZ8-1AT-6DE | AZ8-1AT-6DH | AZ8-1AH-24DE | AZ8-1AT-24DH |
AZ8-1AT-12D | AZ8-1AT-24D | AZ8-1AT-12DH | AZ8-1AT-5DH |