Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5915-01-058-1323 Item Description: Filter Low Pass | 5915 | 010581323 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
7 | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
J180 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
LOW PASS | ABHP | OVERALL LENGTH1 420 INCHES MAXIMUM |
LOW PASS | ABKW | OVERALL HEIGHT0 520 INCHES MAXIMUM |
LOW PASS | ADAQ | BODY LENGTH1 020 INCHES MAXIMUM |
LOW PASS | ADAT | BODY WIDTH0 770 INCHES MAXIMUM |
LOW PASS | AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH0 730 INCHES NOMINAL |
LOW PASS | AECR | VIBRATION RESISTANCE RANGE IN HERTZ10 0 TO 2000 0 |
LOW PASS | AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0 480 INCHES NOMINAL |
LOW PASS | AFGA | OPERATING TEMP RANGE-25 0 TO 50 0 DEG CELSIUS |
LOW PASS | AHAJ | REFERENCE FREQUENCY PER FUNCTION30 0 MEGAHERTZ BLANK |
LOW PASS | AHAU | INPUT IMPEDANCE PER FUNCTION WLOAD50 0 OHMS BLANK |
LOW PASS | AHAV | OUTPUT IMPEDANCE PER FUNCTION WSOURCE ACROSS INPUT50 0 OHMS BLANK |
LOW PASS | AHBZ | VOLTAGE STANDING WAVE RATIO PER FUNCTION1 5 BLANK |
LOW PASS | AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC |
LOW PASS | AKNA | INCLOSURE TYPEENCASED |
LOW PASS | AXHR | MOUNTING FACILITY TYPE AND QUANTITY2 THREADED HOLE |
LOW PASS | CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS2 0 BLANK |
LOW PASS | CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY1 SOLDER STUD INPUT 1ST FUNCTION |
LOW PASS | CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION25 00 MEGAHERTZ BLANK AND 35 00 MEGAHERTZ BLANK AND 50 00 MEGAHERTZ BLANK AND 100 00 MEGAHERTZ BLANK |
LOW PASS | CQJX | NOMINAL THREAD SIZE0 112 INCHES |
LOW PASS | CRBB | FREQUENCY BAND WIDTH PER FUNCTION25 00 MEGAHERTZ BLANK AND 35 00 MEGAHERTZ BLANK |
LOW PASS | CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS1 0 MAXIMUM BLANK AND 1 0 MAXIMUM BLANK AND 40 0 MINIMUM BLANK AND 40 0 MINIMUM BLANK |
LOW PASS | STYL | STYLE DESIGNATORRECTANGULAR TERMINALTERMINALS ON OPPOSITE SURFACES |
J18000 | J1800AF | J1806 07 34 | J181-237-16 |
J180-1610 | J1808-3 | J18000-4 | J1805 |
J180 14 4 | J1803 | J181 | J181 |
J1805 | J18000 | J18000-4 | J180X4 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote