MRC | Criteria | Characteristic |
---|---|---|
THSD | THREAD SERIES DESIGNATOR | UNC SECOND MOUNTING FACILITY |
AAJF | THREAD DIRECTION | RIGHT-HAND SECOND MOUNTING FACILITY |
APNQ | ARC QUENCHING METHOD | AIR |
ABMK | OVERALL WIDTH | 3.090 INCHES MAXIMUM |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SECOND MOUNTING FACILITY |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.199 INCHES NOMINAL FIRST MOUNTING FACILITY |
AKDX | WINDING QUANTITY | 1 |
AFJN | III FRAGILITY FACTOR | MODERATELY RUGGED |
CBME | III CUBIC MEASURE | 45.392 CUBIC INCHES |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC AND 15.0 AMPERES DC RESISTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 240.0 AC AND 30.0 DC |
APNP | DUTY TYPE | CONTINUOUS |
CMLP | THREAD QUANTITY PER INCH | 32 SECOND MOUNTING FACILITY |
CWJB | ENERGIZING ELEMENT POWER RATING | 8.0 WATTS |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
ABKW | OVERALL HEIGHT | 4.520 INCHES MAXIMUM |
ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR FIRST MOUNTING FACILITY RECTANGULAR SECOND MOUNTING FACILITY |
AKSL | III PURPOSE FOR WHICH DESIGNED | GENERAL |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
CRXH | TIME DELAY | 1.00 MINUTES MINIMUM AND 10.00 MINUTES MAXIMUM ADJUSTABLE RELEASE TIME |
ABHP | OVERALL LENGTH | 3.250 INCHES MAXIMUM |
AJSS | FREQUENCY IN HERTZ | 60.0 NOMINAL |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 6 UNTHREADED HOLE FIRST MOUNTING FACILITY 4 THREADED HOLE SECOND MOUNTING FACILITY |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.880 INCHES NOMINAL FIRST MOUNTING FACILITY 1.750 INCHES NOMINAL SECOND MOUNTING FACILITY |
AAJD | THREAD CLASS | 2B SECOND MOUNTING FACILITY |
BBRG | III STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
AEBW | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT | 0.750 INCHES MINIMUM AND 1.500 INCHES MAXIMUM FIRST MOUNTING FACILITY 0.500 INCHES NOMINAL SECOND MOUNTING FACILITY |
TTQY | TERMINAL TYPE AND QUANTITY | 8 SCREW ALL FUNCTIONS |
ADTV | III CASE MATERIAL | PLASTIC |
APCN | COIL QUANTITY | 1 |