5905-00-422-1427 Item Description: RESISTOR,FIXED,FILM | 5905 | 004221427 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
R170H1002F | 3 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -300.0/+300.0 |
AAPP | ELECTRICAL RESISTANCE | 10.000 KILOHMS |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -1.000/+1.000 |
AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 70.0 |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 165.0 |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0/+165.0 |
AAQZ | INCLOSURE METHOD | HERMETICALLY SEALED |
AARB | TERMINAL TYPE | WIRE LEAD |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABPM | BODY DIAMETER | 0.155 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0.435 INCHES NOMINAL |
AEFB | POWER DISSIPATION RATING IN WATTS | 0.250 FREE AIR |
STYL | STYLE DESIGNATOR | AXIAL TERMINAL EACH END |
163-0059 | 163 0009 7 | 163-003-510 | 163-001-000-000 |
163-0-00-00-2 | 163-001 | 163-0-00-03 | 163-0-00-06 |
163-0-00-03 | 163-0-00-00 | 163 0008 9 | 163-0-60 |
163-0-00-00-1 | 163-0056 | 163-001-000 | 163-0-00-00-2 |