Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6145-01-408-2792 Item Description: Cable Special Purpo | 6145 | 014082792 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | S | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
516-015-011 | 5 | 1 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
SR-1 | SPEC/STD CONTROLLING DATA | |
CXCW | CONDUCTOR FORM | STRANDED ALL CONDUCTORS |
ADVN | CROSS-SECTIONAL HEIGHT | 0.100 INCHES NOMINAL |
CXDG | STRAND AWG SIZE PER CONDUCTOR | 34 ALL CONDUCTORS |
PMLC | III PRECIOUS MATERIAL AND LOCATION | SURFACE ALL CONDUCTORS. SILVER |
CXDQ | CONDUCTOR ARRANGEMENT AND QUANTITY | 2 TWISTED TOGETHER W/NO OUTER COVERING |
BLNZ | STRAND QUANTITY PER CONDUCTOR | 19 ALL CONDUCTORS |
HUES | COLOR | WHITE 1ST POSITION PRIMARY INSULATION FIRST CONDUCTOR BLACK 1ST POSITION PRIMARY INSULATION SECOND CONDUCTOR |
SR-1 | MANUFACTURERS CODE | 81349 |
CXDC | ROUND CONDUCTOR SIZE | 22 AWG ALL CONDUCTORS |
ADWH | CROSS-SECTIONAL WIDTH | 0.050 INCHES NOMINAL |
AMQN | CONDUCTOR QUANTITY | 2 |
AAGR | CROSS-SECTIONAL SHAPE STYLE | TWIST |
SFTT | SURFACE TREATMENT | SILVER CORE CONDUCTOR ALL CONDUCTORS |
CXFK | VOLTAGE RATING | 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | ASTM B298 ASSN STD SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
STDC | SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | ASTM B298 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
MATT | MATERIAL | COPPER CORE CONDUCTOR ALL CONDUCTORS PLASTIC POLYTETRAFLUOROETHYLENE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS |
SR-1 | NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MIL-C-55021/2 |
SR-1 | DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | E22C92-0U |
PRMT | III PRECIOUS MATERIAL | SILVER |
ABJH | TEMP RATING | -65.0 DEG CELSIUS AND 200.0 DEG CELSIUS |
ASGF | TRACER COLOR | RED SINGLE TRACER FIRST CONDUCTOR |
516-0-100PSI | 516-00028-01 | 516-0003-38 | 516-0-3000 |
516-0-3000 | 516-000-3-28 | 516-0002 | 516-0003-38 |
516-0002-505 | 516-000 | 516-000 | 516-0003-502 |
516-00028-13 | 516-00012-00 | 516-00028-03 | 516-000-3-28 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote