Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6145-01-384-5352 Item Description: Cable Special Purpo | 6145 | 013845352 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Ntp-1222sj-2k | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
CXCW | CONDUCTOR FORM | STRANDED ALL CONDUCTORS |
CXDC | ROUND CONDUCTOR SIZE | 22 AWG ALL CONDUCTORS |
FEAT | SPECIAL FEATURES | EACH PAIR HAS ONE BLACK AND ONE WHITE WIRE. OUTER JACKET COLOR MAY BE BLACK OR WHITE ,BLACK IS PREFERRED.EACH SUBCABLE JACKET IS INDIVIDUALLY IDENTIFIED BY COLOR STRIPES ON WHITE JACKETS . |
CXDT | GROUP QUANTITY | 12 |
AMQN | CONDUCTOR QUANTITY | 24 |
CXDQ | CONDUCTOR ARRANGEMENT AND QUANTITY | 12 TWISTED PAIR |
BLNZ | STRAND QUANTITY PER CONDUCTOR | 19 ALL CONDUCTORS |
CXFK | VOLTAGE RATING | 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS |
MATT | MATERIAL | COPPER CORE CONDUCTOR ALL CONDUCTORS PLASTIC POLYVINYL CHLORIDE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS PLASTIC POLYAMIDE 2ND POSITION JACKET ALL CONDUCTORS COPPER 3RD POSITION SHIELD BRAID, METALLIC ALL GROUPS PLASTIC POLYVINYL CHLORIDE 4TH POSITION JACKET ALL GROUPS COPPER 5TH POSITION SHIELD BRAID, METALLIC CABLE ALUMINUM AND PLASTIC POLYESTER 6TH POSITION SHIELD FOIL CABLE COPPER 7TH POSITION SHIELD BRAID, METALLIC CABLE PLASTIC POLYVINYL CHLORIDE 8TH POSITION JACKET CABLE |
AAGR | CROSS-SECTIONAL SHAPE STYLE | ROUND |
SFTT | SURFACE TREATMENT | TIN CORE CONDUCTOR ALL CONDUCTORS TIN 3RD POSITION SHIELD BRAID, METALLIC ALL GROUPS TIN 5TH POSITION SHIELD BRAID, METALLIC CABLE TIN 7TH POSITION SHIELD BRAID, METALLIC CABLE |
CXDG | STRAND AWG SIZE PER CONDUCTOR | 34 ALL CONDUCTORS |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | ASTM B33 ASSN STD SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
STDC | SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | ASTM B33 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
CXDY | CONDUCTOR GROUPING ARRANGEMENT TYPE AND QUANTITY | 1 TWISTED PAIR ALL GROUPS |
ABJH | TEMP RATING | -55.0 DEG CELSIUS AND 105.0 DEG CELSIUS |
ADVL | CROSS SECTION OUTSIDE DIAMETER | 0.929 INCHES NOMINAL |
NTP-1662 | NTP-25 | NTP-25 | NTP-1661 |
NTP-3724SJ-2K | NTP-3002X | NTP-3002 | NTP-1442 |
NTP-2402 | NTP-25 | NTP-1441 | NTP-1620J-PU |
NTP-1920SJ-2K | NTP-1902 | NTP 322SJ | NTP-1801 |