MRC | Criteria | Characteristic |
---|---|---|
SR-5 | DESIGN CONTROL REFERENCE | 1107001 |
RDAL | III REFERENCE DATA AND LITERATURE | 33A1-3-583-1 |
AEJZ | DEPTH | 26.250 INCHES NOMINAL |
ANPZ | INCLOSURE FEATURE | SINGLE ITEM W/HOUSING |
FEAT | SPECIAL FEATURES | FULL INSTRUMENTATION IS PROVIDED FOR THE VOLTAGE, CURRENT, LOAD TEMPERATURE; CONTROLLABLE THROUGH IEEE-488 BUS;RACK MOUNTED CHASSIS WITH PLUG-IN LOAD MODULES(2);LOAD INPUT VOLTAGES 5 TO200 VDC, SET CURRENT 0 TO 240 AMPS, MAXIMUM RATED POWER 2500 WATTS, DYNAMIC RESPONSE 750 TO 40 MICROSEC, LOAD TEMPERATURE RANGE 15 TO 90 DEGREES C |
FAAZ | PHASE | SINGLE |
ACYN | AC VOLTAGE RATING | 103.0 VOLTS MINIMUM AND 129.0 VOLTS MAXIMUM |
AQXY | TEST TYPE FOR WHICH DESIGNED | PROVIDES PROGRAMMABLE ELECTRICAL LOADS |
SR-5 | THE MANUFACTURERS DATA | |
AGAV | III END ITEM IDENTIFICATION | POWER SUPPLY TEST STATION NSN 6625-01-399-1759 |
ABGL | WIDTH | 19.000 INCHES NOMINAL |
SR-5 | MANUFACTURERS CODE | 24862 |
ACZB | FREQUENCY RATING | 47.0 HERTZ MINIMUM AND 63.0 HERTZ MAXIMUM |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
ALSF | INTERNAL BATTERY ACCOMMODATION | NOT INCLUDED |
HGTH | HEIGHT | 10.500 INCHES NOMINAL |
110-000-214 | 110.000.137 | 110.000.444 | 110.000.219 |
110-00-00-00-00 | 110-000-002 | 110-00-008 | 110.000.190 |
110.000.178 | 110.000.436 | 110.000.208 | 110-00-008 |
110-00 | 110.000.438 | 110.000.284 | 110.000.436X |