Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5962-01-005-5120 Item Description: Microcircuit Linear | 5962 | 010055120 | 0 | N | B | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | B | U | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Ml1520 Bha | 1 | 1 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ADAQ | BODY LENGTH | 0.240 INCHES MINIMUM AND 0.290 INCHES MAXIMUM |
ADAT | BODY WIDTH | 0.240 INCHES MINIMUM AND 0.260 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 0.030 INCHES MINIMUM AND 0.070 INCHES MAXIMUM |
AEHX | MAXIMUM POWER DISSIPATION RATING | 240.0 MILLIWATTS |
AFGA | OPERATING TEMP RANGE | -55.0/+125.0 DEG CELSIUS |
AFJQ | STORAGE TEMP RANGE | -65.0/+150.0 DEG CELSIUS |
AGAV | END ITEM IDENTIFICATION | AIRCRAFT TYPE FTF-15A |
CBBL | FEATURES PROVIDED | HERMETICALLY SEALED AND MONOLITHIC AND NEGATIVE OUTPUTS AND POSITIVE OUTPUTS AND INTERNALLY COMPENSATED |
CQSJ | INCLOSURE MATERIAL | CERAMIC AND GLASS |
CQSZ | INCLOSURE CONFIGURATION | FLAT PACK |
CQZP | INPUT CIRCUIT PATTERN | 6 INPUT |
CSSL | DESIGN FUNCTION AND QUANTITY | 1 AMPLIFIER, OPERATIONAL, GENERAL PURPOSE |
CTFT | CASE OUTLINE SOURCE AND DESIGNATOR | T0-91 JOINT ELECTRON DEVICE ENGINEERING COUNCIL |
CWSG | TERMINAL SURFACE TREATMENT | TIN |
CZEN | VOLTAGE RATING AND TYPE PER CHARACTERISTIC | -8.0 VOLTS MINIMUM POWER SOURCE AND 8.0 VOLTS MAXIMUM POWER SOURCE |
CZEQ | TIME RATING PER CHACTERISTIC | 150.00 NANOSECONDS MAXIMUM PROPAGATION DELAY TIME, LOW TO HIGH LEVEL OUTPUT |
TEST | TEST DATA DOCUMENT | 03640-6088570 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAW |
TTQY | TERMINAL TYPE AND QUANTITY | 10 FLAT LEADS |
ML1-100YF1 | ML1-34.06-S | ML1-100RF1 | ML1-100Y |
ML1-100Y | ML1-20G10L1 | ML1-100R | ML1-34.06-S |
ML1-205E | ML1-100G | ML1-40AMP | ML1-20R10F1 |
ML1-100Y | ML1 0-LY | ML1-20Y10F1 | ML1-2P600V15A |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote