Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-269-0712 Item Description: Transformer Power | 5950 | 012690712 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Tm-1656 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABTB | MOUNTING HOLE DIAMETER | 0.140 INCHES NOMINAL SINGLE GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 1.200 INCHES MAXIMUM |
ADAR | BODY OUTSIDE DIAMETER | 1.900 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 155.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 1 SINGLE GROUP |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 4 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 1.0 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 10.0 MILLIAMPERES AC MINIMUM SINGLE COMPONENT 1ST SECONDARY AND 200.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 25.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 400.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 17.8 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 108.00 AC VOLTS MINIMUM SINGLE COMPONENT SINGLE PRIMARY AND 118.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 11.60 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 26.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 89.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 54.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 13 TURRET |
TM-0022 | TM-03101-08 | TM-007 | TM-013 |
TM-0009 | TM-03201-12 | TM 03 | TM-0008 |
TM-0009 | TM 04123 08 | TM-03101 | TM-023 |
TM-03201-12 | TM-02101-01 | TM-0508-A-4 | TM-0008 |