Note : We Will Not Share Your Information To Any Third Parties.
MRC | Criteria | Characteristic |
---|---|---|
APTS | OUTPUT FREQUENCY RATING | 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
CWGW | POWER SUPPLY OUTPUT CURRENT/VOLTAGE CHARACTERISTICS | LIMITING CURRENT MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
ABKW | OVERALL HEIGHT | 150.0 MILLIMETERS NOMINAL |
CWHF | OUTPUT CONNECTION QUANTITY | 4 MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
CBBL | FEATURES PROVIDED | BATTERY CHARGER AND CALIBRATED OUTPUT SIGNAL AND CIRCUIT BREAKER AND CIRCUIT OVERLOAD PROTECTION DEVICE AND EMI FILTER AND INPUT VOLTAGE RANGE SWITCH AND OVER CURRENT PROTECTOR AND VOLTAGE ADJUSTMENT |
CWHT | INPUT CONNECTION QUANTITY | 1 SINGLE OPERATING POWER RQMT |
CWHY | BATTERY FEATURE AND TYPE | RECHARGEABLE LEAD ACID CELL |
AYNH | OPERATING AMBIENT TEMP RANGE | 0.1 TO 30.0 DEG CELSIUS |
CWJF | BATTERY LOCATION | INTERNAL |
BGHY | OUTPUT CONTROL TYPE | CURRENT LIMIT AND VOLTAGE ADJUSTMENT MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
APNX | INPUT VOLTAGE RATING | 240.0 AC VOLTS MAXIMUM SINGLE OPERATING POWER RQMT |
ABHP | OVERALL LENGTH | 330.0 MILLIMETERS NOMINAL |
BGQR | OUTPUT WATTAGE RATING | 300.0 WATTS NOMINAL MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
ANPM | INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT |
CWWB | BATTERY RECOVERY TIME | 300.0 |
ANRQ | FREQUENCY REGULATION PERCENT | 0.5 MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
AMQY | INSTALLATION DESIGN | BENCH |
CXNJ | POWER SUPPLIES PROGRAMMED PER SYSTEM | 4 |
AKAE | MAXIMUM OPERATING ALTITUDE RATING | 3000.0 METERS |
FEAT | SPECIAL FEATURES | INPUT VOLTAGE ADJUSTABLE IN FIVE INCREMENTS FROM A HIGH OF 220.0 TO 240.0 VAC, GREATER THAN 196.0 VAC, GREATER THAN 184.0 VAC, GREATER THAN 172.0 VAC, TO A LOW OF 160.0 VAC TO COMPENSA TE FOR BROWNOUT CONDITIONS; INPUT LINEUSES AN IEC 320 MALE APPLIANCE COUPLER; OPTION SWITCHES ALLOW FOR CUSTOMIZATION OF TRANSFER VOLTAGE (ON BATTERY) IN A STEPPED APPROXIMATION TO SINE WAVE AT 225.0 VAC PLUS OR MINUS 5 PERCENT, SET ALARM, AND CONTROL OUTPUT FREQUENCY SETTINGS; UNIT HAS 4 IEC FEMALE APPLIANCE COUPLERS; AMBIENT OPERATING HUMIDITY PLUS 0.0 TO 95.0 PERCENT (NON-CONDENSING); HOT SWAPPABLE USER-REPLACEABLE BATTERIES; WEIGHS 7.0 KG; LOW VOLTAGE DIRECTIVE 73/23/EEC, GS LICENSES BY VDE PER STANDARD EN60950 AND EN50091; EMC DIRECTIVE 89/336/EEC, C-TICK APPROVED, EN5022 (CISPR22) AND EN50082-1 |
ABMK | OVERALL WIDTH | 90.0 MILLIMETERS NOMINAL |
CWGH | OUTPUT CURRENT RATING | 500.0 AC VOLT-AMPERE NOMINAL MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
CWGN | OUTPUT PHASE | SINGLE MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
APPA | OUTPUT VOLTAGE RATING | 225.00 AC VOLTS NOMINAL MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
417-0029-025 | 417-0029-025 | 417-0037-055 | 417-0022-044 |
417-00021-01 | 417-0026-063 | 417-00009-01 | 417-0030-0100 |
417-005 | 417-0029-025 | 417-0040-0100 | 417-0006 |
417-00002-39 | 417-0031-003 | 417-0007 | 417-0007 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote