MRC | Criteria | Characteristic |
---|---|---|
AYHQ | ENGINE MANUFACTURER IDENTIFYING NUMBER | F163 |
SR-5 | DESIGN CONTROL REFERENCE | 903 043 |
AMZE | ROTATIONAL SPEED RATING IN RPM | 1800.0 |
APGF | DESIGN TYPE | GENERATOR |
SR-5 | MANUFACTURERS CODE | 40608 |
CDRS | MINIMUM CURRENT AT SPECIFIED VOLTAGE | 45 AMP AT 95 V |
CDRT | MAXIMUM CURRENT AT SPECIFIED VOLTAGE | 400 AMP AT 55 V |
CDRW | OPERATOR TYPE FOR WHICH DESIGNED | SINGLE |
CDRY | REMOTE CONTROL DESIGN | NOT INCLUDED |
CDRZ | AUXILIARY POWER OUTPUT DESIGN | INCLUDED |
BFLS | OUTPUT PHASE | SINGLE |
SR-5 | THE MANUFACTURERS DATA | |
ANLH | POWER OUTPUT RATING | 3.0 KILOWATTS |
APTS | OUTPUT FREQUENCY RATING | 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM |
ANPP | OUTPUT VOLTAGE RATING IN VOLTS | 120.0 MINIMUM AND 240.0 MAXIMUM |
ATJK | POWER SOURCE | GASOLINE ENGINE |
ATJL | ENGINE MANUFACTURER NAME | TELEDYNE CONTINENTAL |
ANCY | HORSEPOWER RATING | 36.0 |
ANPN | OUTPUT CURRENT TYPE | AC |
ANYP | OUTPUT CURRENT RATING IN AMPS | 300.0 NOMINAL |
CDRR | ARC CURRENT TYPE | DC |
AAXX | MOUNTING TYPE | SKID |