Note : We Will Not Share Your Information To Any Third Parties.
MRC | Criteria | Characteristic |
---|---|---|
AFGQ | FREQUENCY RANGE RATING | 0.045 TO 11.000 GIGAHERTZ |
SR-5 | DESIGN CONTROL REFERENCE | 448312-100 |
BHZJ | METER ACCURACY RANGE IN PERCENT | -1.0 TO 1.0 |
SR-5 | THE MANUFACTURERS DATA | |
ABHP | OVERALL LENGTH | 22.000 INCHES NOMINAL |
BHGJ | PLUG-IN UNIT QUANTITY | 6 |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL |
AMND | INPUT IMPEDANCE RATING | 50.0 OHMS NOMINAL |
FAAZ | PHASE | SINGLE |
ANLC | FREQUENCY BAND QUANTITY | 6 |
ACYN | AC VOLTAGE RATING | 115.0 VOLTS NOMINAL |
APQB | UNIT TYPE | PLUG-IN |
BHZH | METER SCALE RANGE | 0.5 TO 10 MW FULL |
ANLE | INDIVIDUAL CHANNEL FREQUENCY | 120.0 MEGAHERTZ NOMINAL |
ABKW | OVERALL HEIGHT | 16.000 INCHES NOMINAL |
BHZG | INDIVIDUAL PLUG-IN UNIT FREQUENCY | 1.0 GIGAHERTZ AND 2.4 GIGAHERTZ AND 4.1 GIGAHERTZ AND 8.1 GIGAHERTZ AND 11.0 GIGAHERTZ AND 500.0 MEGAHERTZ |
AKYN | FURNISHED ITEMS AND QUANTITY | INSTRUCTION BOOK,1; INPUT POWER CABLE,1; RF CABLE,1; 10 DB ATTENUATOR,1 |
BHBG | RECORDING DEVICE TYPE | CAMERA AND ELECTRONIC VIDEO |
ABMK | OVERALL WIDTH | 14.000 INCHES NOMINAL |
SR-5 | MANUFACTURERS CODE | 82577 |
ANLD | FREQUENCY CHANNEL QUANTITY | 1 |
AREL | FREQUENCY CALIBRATION ACCURACY RANGE IN PERCENT | -0.1 TO 0.1 |
BHZK | CATHODE RAY TUBE DISPLAYED INFORMATION | W PER MC VERSUS FREQ OR VIDEO RESPONSE VERSUS FREQ |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote