5915-00-632-2375 Item Description: Filter Low Pass | 5915 | 006322375 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
2632 | 2 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
LOW PASS | ABHP | OVERALL LENGTH7 500 INCHES NOMINAL |
LOW PASS | ABKW | OVERALL HEIGHT1 250 INCHES NOMINAL |
LOW PASS | ADAQ | BODY LENGTH6 000 INCHES NOMINAL |
LOW PASS | ADAT | BODY WIDTH3 000 INCHES NOMINAL |
LOW PASS | AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH5 625 INCHES NOMINAL |
LOW PASS | AECR | VIBRATION RESISTANCE RANGE IN HERTZ10 0 TO 55 0 |
LOW PASS | AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH2 625 INCHES NOMINAL |
LOW PASS | AFGA | OPERATING TEMP RANGE0 0 TO 50 0 DEG CELSIUS |
LOW PASS | AHAJ | REFERENCE FREQUENCY PER FUNCTION17 0 MEGAHERTZ BLANK |
LOW PASS | AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION50 0 OHMS BLANK |
LOW PASS | AHAS | LOAD IMPEDANCE PER FUNCTION50 0 OHMS BLANK |
LOW PASS | AHBZ | VOLTAGE STANDING WAVE RATIO PER FUNCTION1 5 BLANK |
LOW PASS | AHCH | AVERAGE POWER RATING PER FUNCTION100 0 WATTS BLANK |
LOW PASS | AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC |
LOW PASS | AKNA | INCLOSURE TYPEENCASED |
LOW PASS | AXHR | MOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE |
LOW PASS | CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS0 5 BLANK |
LOW PASS | CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR RECEPTACLE INPUT 1ST FUNCTION |
LOW PASS | CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION2 00 MEGAHERTZ BLANK AND 32 00 MEGAHERTZ BLANK AND 80 00 MEGAHERTZ BLANK AND 1 00 GIGAHERTZ BLANK |
LOW PASS | CQJX | NOMINAL THREAD SIZE0 112 INCHES |
LOW PASS | CRBB | FREQUENCY BAND WIDTH PER FUNCTION2 00 MEGAHERTZ BLANK AND 32 00 MEGAHERTZ BLANK |
LOW PASS | CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS1 0 MAXIMUM BLANK AND 1 0 MAXIMUM BLANK AND 100 0 MINIMUM BLANK AND 100 0 MINIMUM BLANK |
LOW PASS | CRBN | VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION2 0 MEGAHERTZ BLANK AND 32 0 MEGAHERTZ BLANK |
LOW PASS | STYL | STYLE DESIGNATORRECTANGULAR TERMINALTERMINALS ON OPPOSITE SURFACES |