5915-00-403-2634 Item Description: Filter Band Pass | 5915 | 004032634 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
7 | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
2510-2 | 2 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABKW | OVERALL HEIGHT | 8.500 INCHES NOMINAL |
ADAQ | BODY LENGTH | 4.490 INCHES MINIMUM AND 4.510 INCHES MAXIMUM |
ADAT | BODY WIDTH | 1.470 INCHES MINIMUM AND 1.530 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 6.700 INCHES MINIMUM AND 6.800 INCHES MAXIMUM |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.188 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 3.950 INCHES MINIMUM AND 4.050 INCHES MAXIMUM |
AECR | VIBRATION RESISTANCE RANGE IN HERTZ | +10.0/+2000.0 |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 3.990 INCHES MINIMUM AND 4.010 INCHES MAXIMUM |
AFGA | OPERATING TEMP RANGE | -29.0/+70.0 DEG CELSIUS |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 312.5 MEGAHERTZ BLANK |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS BLANK |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS BLANK |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE BLANK |
AHBZ | VOLTAGE STANDING WAVE RATIO PER FUNCTION | 1.3 BLANK |
AHCH | AVERAGE POWER RATING PER FUNCTION | 15.0 WATTS BLANK |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
CBBL | FEATURES PROVIDED | TUNABLE |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 3.0 BLANK |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 137.50 MEGAHERTZ BLANK AND 225.00 MEGAHERTZ BLANK AND 400.00 MEGAHERTZ BLANK AND 487.50 MEGAHERTZ BLANK |
CQRG | BODY MATERIAL | METAL |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 225.00 MEGAHERTZ BLANK AND 400.00 MEGAHERTZ BLANK |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 3.0 MINIMUM BLANK AND 40.0 MAXIMUM BLANK |
CRBN | VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION | 225.0 MEGAHERTZ BLANK AND 400.0 MEGAHERTZ BLANK |
CWZH | FREQUENCY TUNING METHOD | VOLTAGE TUNABLE |
CWZQ | TUNABLE FREQUENCY RANGE | 225.0 MEGAHERTZ MINIMUM AND 400.0 MEGAHERTZ MAXIMUM |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |