Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5985-01-303-4819 Item Description: Waveguide Assembly | 5985 | 013034819 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
7 | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Mtps62-501-N-3a | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
AAJD | THREAD CLASS | 2B SECOND FLANGE ALL CONNECTION FACILITIES |
AAJF | THREAD DIRECTION | RIGHT-HAND SECOND FLANGE ALL CONNECTION FACILITIES |
AHRV | TUBING WALL CONSTRUCTION STYLE | CORRUGATED SINGLE TUBING SEGMENT |
AHSF | FLANGE QUANTITY | 2 |
AHSX | FLANGE INSIDE WIDTH | 0.620 INCHES MINIMUM SECOND FLANGE AND 0.624 INCHES MAXIMUM SECOND FLANGE |
AHSX | FLANGE INSIDE WIDTH | 0.703 INCHES MINIMUM FIRST FLANGE AND 0.708 INCHES MAXIMUM FIRST FLANGE |
AHSY | FLANGE INSIDE HEIGHT | 0.309 INCHES MINIMUM SECOND FLANGE AND 0.311 INCHES MAXIMUM SECOND FLANGE |
AHSY | FLANGE INSIDE HEIGHT | 0.505 INCHES MINIMUM FIRST FLANGE AND 0.511 INCHES MAXIMUM FIRST FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 1.298 INCHES MINIMUM FIRST FLANGE AND 1.328 INCHES MAXIMUM FIRST FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 1.298 INCHES MINIMUM SECOND FLANGE AND 1.328 INCHES MAXIMUM SECOND FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 1.298 INCHES MINIMUM FIRST FLANGE AND 1.328 INCHES MAXIMUM FIRST FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 1.298 INCHES MINIMUM SECOND FLANGE AND 1.328 INCHES MAXIMUM SECOND FLANGE |
AHTD | FLANGE DEPTH | 0.360 INCHES MINIMUM SECOND FLANGE AND 0.390 INCHES MAXIMUM SECOND FLANGE |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.341 INCHES MINIMUM FIRST FLANGE ALL CONNECTION FACILITIES AND 0.347 INCHES MAXIMUM FIRST FLANGE ALL CONNECTION FACILITIES |
CQHN | WAVEGUIDE OUTSIDE WIDTH | 1.250 INCHES NOMINAL |
CRLB | WAVEGUIDE INSIDE HEIGHT | 0.497 INCHES NOMINAL |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 THREADED HOLE SECOND FLANGE ALL CONNECTION FACILITIES |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE FIRST FLANGE ALL CONNECTION FACILITIES |
CTCJ | FLANGE STYLE | CHOKE TYPE SECOND FLANGE |
CTCJ | FLANGE STYLE | COVER TYPE FIRST FLANGE |
CTFD | WAVEGUIDE LENGTH | 3.000 INCHES NOMINAL |
MATT | MATERIAL | RUBBER SINGLE TUBING SEGMENT |
THSD | THREAD SERIES DESIGNATOR | UNC SECOND FLANGE ALL CONNECTION FACILITIES |
MATT | MATERIAL | ALUMINUM ALLOY ALL FLANGE |
STYL | III STYLE DESIGNATOR | STRAIGHT TYPE |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SECOND FLANGE ALL CONNECTION FACILITIES |
FLEX | FLEXIBILITY | FLEXIBLE SINGLE TUBING SEGMENT |
AHTD | FLANGE DEPTH | 0.298 INCHES MINIMUM FIRST FLANGE AND 0.328 INCHES MAXIMUM FIRST FLANGE |
CRFH | WAVEGUIDE INSIDE WIDTH | 1.122 INCHES NOMINAL |
CSFC | WAVEGUIDE OUTSIDE HEIGHT | 0.625 INCHES NOMINAL |
MTP-012M-MM | MTP-012F-MM | MTP 4N90 | MTP-44U |
MTP-1702 | MTP-44-G | MTP-012M-SM | MTP-520 |
MTP 4N90 | MTP-003M | MTP-1502 | MTP-64-U |
MTP-012F-SM | MTP-003 | MTP-5714-P2 | MTP-48 H6 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote