Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5985-00-110-7087 Item Description: Waveguide Assembly | 5985 | 001107087 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
7 | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Adc1020-00 | 2 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
AHRV | TUBING WALL CONSTRUCTION STYLE | CORRUGATED SECOND TUBING SEGMENT |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS FIFTH TUBING SEGMENT |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS FIRST TUBING SEGMENT |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS FOURTH TUBING SEGMENT |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS SIXTH TUBING SEGMENT |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS THIRD TUBING SEGMENT |
AHSF | FLANGE QUANTITY | 2 |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.107 INCHES MINIMUM ALL FLANGES ALL CONNECTION FACILITIES AND 0.112 INCHES MAXIMUM ALL FLANGES ALL CONNECTION FACILITIES |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.10 |
AHTX | INSERTION LOSS IN DECIBELS | 0.25 |
CQHN | WAVEGUIDE OUTSIDE WIDTH | 0.699 INCHES MINIMUM AND 0.705 INCHES MAXIMUM |
CRFH | WAVEGUIDE INSIDE WIDTH | 0.620 INCHES MINIMUM AND 0.625 INCHES MAXIMUM |
CRLB | WAVEGUIDE INSIDE HEIGHT | 0.309 INCHES MINIMUM AND 0.314 INCHES MAXIMUM |
CSFC | WAVEGUIDE OUTSIDE HEIGHT | 0.388 INCHES MINIMUM AND 0.394 INCHES MAXIMUM |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE ALL FLANGES ALL CONNECTION FACILITIES |
FLEX | FLEXIBILITY | FLEXIBLE SECOND TUBING SEGMENT |
FLEX | FLEXIBILITY | RIGID FIFTH TUBING SEGMENT |
FLEX | FLEXIBILITY | RIGID FIRST TUBING SEGMENT |
FLEX | FLEXIBILITY | RIGID FOURTH TUBING SEGMENT |
FLEX | FLEXIBILITY | RIGID SIXTH TUBING SEGMENT |
FLEX | FLEXIBILITY | RIGID THIRD TUBING SEGMENT |
SFTT | SURFACE TREATMENT | CHROMATE SINGLE TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
ZZZV | FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |
ADC-010-1 | ADC-001-C | ADC-007-4 | ADC-002 |
ADC-002-1-EU | ADC-002A-2 | ADC-002F-1 | ADC-001-A |
ADC-001-B | ADC-002-5 | ADC-002A-2-RC | ADC-003-1 |
ADC-005-1 | ADC-00301-602 | ADC-007-1 | ADC-002A-1 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote