5985-01-187-4962 Item Description: Waveguide Assembly | 5985 | 011874962 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
7 | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
5187778 | 6 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
AAJD | THREAD CLASS | 2B FIRST FLANGE ALL CONNECTION FACILITIES |
AAJF | THREAD DIRECTION | RIGHT-HAND FIRST FLANGE ALL CONNECTION FACILITIES |
ACJL | BEND ANGLE IN DEG | 90.0 ALL BENDS E-PLANE |
AHRV | TUBING WALL CONSTRUCTION STYLE | CORRUGATED THIRD TUBING SEGMENT |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS FIFTH TUBING SEGMENT |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS FIRST TUBING SEGMENT |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS FOURTH TUBING SEGMENT |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS SECOND TUBING SEGMENT |
AHSF | FLANGE QUANTITY | 2 |
AHSX | FLANGE INSIDE WIDTH | 0.620 INCHES MINIMUM FIRST FLANGE AND 0.624 INCHES MAXIMUM FIRST FLANGE |
AHSY | FLANGE INSIDE HEIGHT | 0.309 INCHES MINIMUM FIRST FLANGE AND 0.313 INCHES MAXIMUM FIRST FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 1.297 INCHES MINIMUM FIRST FLANGE AND 1.327 INCHES MAXIMUM FIRST FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 1.297 INCHES MINIMUM FIRST FLANGE AND 1.327 INCHES MAXIMUM FIRST FLANGE |
AHTB | FLANGE INSIDE DIAMETER | 0.985 INCHES MINIMUM FIRST FLANGE AND 1.015 INCHES MAXIMUM FIRST FLANGE |
AHTD | FLANGE DEPTH | 0.360 INCHES MINIMUM FIRST FLANGE AND 0.390 INCHES MAXIMUM FIRST FLANGE |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.15 |
AHTX | INSERTION LOSS IN DECIBELS | 0.13 |
CQHN | WAVEGUIDE OUTSIDE WIDTH | 0.699 INCHES MINIMUM AND 0.705 INCHES MAXIMUM |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES FIRST FLANGE ALL CONNECTION FACILITIES |
CRFH | WAVEGUIDE INSIDE WIDTH | 0.620 INCHES MINIMUM AND 0.625 INCHES MAXIMUM |
CRLB | WAVEGUIDE INSIDE HEIGHT | 0.309 INCHES MINIMUM AND 0.314 INCHES MAXIMUM |
CSFC | WAVEGUIDE OUTSIDE HEIGHT | 0.388 INCHES MINIMUM AND 0.394 INCHES MAXIMUM |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 THREADED HOLE FIRST FLANGE ALL CONNECTION FACILITIES |
CTCJ | FLANGE STYLE | CHOKE TYPE FIRST FLANGE |
CXBB | WAVEGUIDE CENTER TO CENTER DISTANCE | 4.940 INCHES MINIMUM AND 4.960 INCHES MAXIMUM |
CXBD | WAVEGUIDE HEIGHT | 1.920 INCHES MINIMUM AND 1.980 INCHES MAXIMUM |
FLEX | FLEXIBILITY | FLEXIBLE THIRD TUBING SEGMENT |
FLEX | FLEXIBILITY | RIGID FIFTH TUBING SEGMENT |
FLEX | FLEXIBILITY | RIGID FIRST TUBING SEGMENT |
FLEX | FLEXIBILITY | RIGID FOURTH TUBING SEGMENT |
FLEX | FLEXIBILITY | RIGID SECOND TUBING SEGMENT |
MATT | MATERIAL | COPPER ALL TUBING SEGMENT |
STYL | III STYLE DESIGNATOR | DOUBLE BEND TYPE |
THSD | THREAD SERIES DESIGNATOR | UNC FIRST FLANGE ALL CONNECTION FACILITIES |
ZZZK | SPECIFICATION/STANDARD DATA | 53711-5187778 MANUFACTURERS SOURCE CONTROL |
ZZZV | FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |
518-000 | 518-000 | 518-000-39 | 518-000-39A |
518-000-156A | 518-000-156A | 518-000-156A | 518-000 |
518-000-155A | 518-000 | 518-000-39A | 518 000 39A |
518+000+2+5+9A | 518-000-155A | 518+000+2+5+9A | 518+000+2+5+9A |