NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5985-00-153-8471 Item Description: Dummy Load Electric | 5985 | 001538471 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
7 | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
13563 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 125.0 |
AAXT | COOLING SYSTEM COOLANT FLOW RATE | 4.0 GALLONS PER MINUTE |
ABHP | OVERALL LENGTH | 10.330 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 3.240 INCHES MINIMUM AND 3.500 INCHES MAXIMUM |
ABPM | BODY DIAMETER | 3.250 INCHES NOMINAL |
AFGQ | FREQUENCY RANGE RATING | +8.500/+11.000 GIGAHERTZ |
AGAV | END ITEM IDENTIFICATION | AIRCRAFT, TOMCAT F-14 |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.10 |
AKNK | VOLTAGE STANDING WAVE RATIO FREQUENCY RANGE | +8.500/+11.000 GIGAHERTZ |
AKRZ | TERMINATION TYPE | WAVEGUIDE FLANGE |
AKSA | WAVEGUIDE FLANGE DESIGNATION | UG138/U-MODIFIED |
AKSC | INTAKE CONNECTION THREAD LOCATION | INTERNAL |
AKSD | DISCHARGE CONNECTION THREAD LOCATION | INTERNAL |
AWNL | INPUT COOLANT TEMP | 80.0 DEG CELSIUS |
BFMF | COOLING METHOD | FORCED LIQUID |
STYL | STYLE DESIGNATOR | WAVEGUIDE MOUNTED |