5905-00-565-8405 Item Description: Resistor Variable N | 5905 | 005658405 | 0 | N | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
8035ekr201 | 3 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAPN | SECTION QUANTITY | 1 |
AAQL | BODY STYLE | RECTANGULAR |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | III OVERALL LENGTH | 0.810 INCHES NOMINAL |
ABJT | TERMINAL LENGTH | 0.200 INCHES NOMINAL |
ABKW | III OVERALL HEIGHT | 0.470 INCHES NOMINAL |
ABMK | III OVERALL WIDTH | 0.190 INCHES NOMINAL |
ABWV | SHAFT DIAMETER | 0.100 INCHES NOMINAL |
ABXF | SHAFT LENGTH | 0.060 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0.750 INCHES NOMINAL |
ADAT | BODY WIDTH | 0.190 INCHES NOMINAL |
ADAU | BODY HEIGHT | 0.270 INCHES NOMINAL |
AEDX | SHAFT STYLE | ROUND, SLOTTED |
AEFD | ACTUATOR TYPE | SINGLE SHAFT |
AEFH | EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 5400.0 NOMINAL |
AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.700 INCHES NOMINAL |
AFJN | III FRAGILITY FACTOR | MODERATELY RUGGED |
APXH | TERMINAL LOCATION | LOWER ADJACENT SIDE TWO ROWS |
AXGY | MOUNTING METHOD | TERMINAL |
AYQR | CENTER TO CENTER DISTANCE BETWEEN TERMINAL ROWS | 0.100 INCHES NOMINAL |
CBBL | FEATURES PROVIDED | HUMIDITY PROOF |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 200.0 OHMS SINGLE SECTION |
CQCK | ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | 5400.0 NOMINAL |
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.300 INCHES NOMINAL |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 150.0 SINGLE SECTION |
CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -100.0 TO 100.0 SINGLE SECTION |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 0.5 FREE AIR SINGLE SECTION |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -10.0 TO 10.0 SINGLE SECTION |
CRSX | ACTUATOR TRAVEL CONTROL FEATURE | CLUTCH |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 85.0 SINGLE SECTION |
TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN |
803-0006A | 803-001-06M10-26PN | 803-001 | 803-0006 |
803-001-06M12-2PN | 803-000-0088 | 803 0009A | 803-0009A |
803-000-0088 | 803- -119721PIE CE47 | 803-0002 | 803 0006A |
803-0007-001 | 803-0001-001 | 803-0007-001 | 803-0003 |