5961-01-396-2006 Item Description: Transistor | 5961 | 013962006 | 0 | N | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
8777b1 | 5 | 1 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABBH | INCLOSURE MATERIAL | METAL |
CTSG | MAXIMUM OPERATING TEMP PER MEASUREMENT POINT | 200.0 DEG CELSIUS JUNCTION |
CTQN | VOLTAGE RATING IN VOLTS PER CHARACTERISTIC | 450.0 MAXIMUM COLLECTOR-TO-EMITTER, SUBSTAINING VOLTAGE, BASE OPEN-CIRCUITED AND 850.0 MAXIMUM COLLECTOR-TO-EMITTER, WITH VOLTAGE BETWEEN BASE AND EMITTER AND 6.0 MAXIMUM EMITTER TO BASE VOLTAGE, STATIC, COLLECTOR OPEN |
TTQY | TERMINAL TYPE AND QUANTITY | 2 PIN AND 1 CASE |
AKPV | MOUNTING FACILITY QUANTITY | 2 |
ABMK | OVERALL WIDTH | 0.980 INCHES MINIMUM AND 1.050 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 0.250 INCHES MINIMUM AND 0.300 INCHES MAXIMUM |
AXGY | MOUNTING METHOD | UNTHREADED HOLE |
CTQX | CURRENT RATING PER CHARACTERISTIC | 15.00 AMPERES MAXIMUM BASE CURRENT, DC AND 20.00 AMPERES MAXIMUM COLLECTOR CURRENT, DC |
ALAS | INTERNAL CONFIGURATION | JUNCTION CONTACT |
ALBA | ELECTRODE INTERNALLY-ELECTRICALLY CONNECTED TO CASE | COLLECTOR |
CTMZ | SEMICONDUCTOR MATERIAL | SILICON |
ABHP | OVERALL LENGTH | 1.510 INCHES MINIMUM AND 1.550 INCHES MAXIMUM |
FEAT | SPECIAL FEATURES | JUNCTION PATTERN ARRANGEMENT: NPN |
ABJT | TERMINAL LENGTH | 0.440 INCHES MINIMUM AND 0.480 INCHES MAXIMUM |
TEST | TEST DATA DOCUMENT | 66948-2001109 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
CTRD | POWER RATING PER CHARACTERISTIC | 250.0 WATTS MAXIMUM TOTAL POWER DISSIPATION |
877-009-012 | 877-009-018 | 877-041 | 877-08928 |
877-014C | 877-009703X-00 | 877-009703Y-00 | 877-008928Y00 |
877-008928Y00 | 877-009-017 | 877-008366X-00 | 877-009703 |
877-009703Y00 | 877-014C | 877-009-021 | 877-009-002 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote