5910-01-397-3340 Item Description: Capacitor Fixed Ele | 5910 | 013973340 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
0180-1085 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
CQJJ | NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 25.0 DC SINGLE SECTION |
ABHP | (NON-CORE DATA) OVERALL LENGTH | 0.271 INCHES MINIMUM AND 0.295 INCHES MAXIMUM |
ADAT | BODY WIDTH | 0.212 INCHES MINIMUM AND 0.236 INCHES MAXIMUM |
AECQ | ELECTRICAL POLARIZATION | POLARIZED |
CRTP | TOLERANCE RANGE PER SECTION | -20.00 TO 20.00 PERCENT SINGLE SECTION |
ABMK | (NON-CORE DATA) OVERALL WIDTH | 0.412 INCHES MINIMUM AND 0.511 INCHES MAXIMUM |
CWJK | CASE MATERIAL | CERAMIC |
AARG | RELIABILITY INDICATOR | ESTABLISHED |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.180 INCHES MINIMUM AND 0.220 INCHES MAXIMUM |
TTQY | TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
CQLH | III DC LEAKAGE AT MAXIMUM OPERATING TEMP | 12.0 MICROAMPERES |
CWQH | DC LEAKAGE AT REFERENCE TEMP | 1.200 MICROAMPERES |
CWSG | III TERMINAL SURFACE TREATMENT | SOLDER |
ADAU | BODY HEIGHT | 0.157 INCHES MINIMUM AND 0.181 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 0.271 INCHES MINIMUM AND 0.295 INCHES MAXIMUM |
CQBQ | CAPACITANCE VALUE PER SECTION | 4.700 MICROFARADS SINGLE SECTION |
ABKW | (NON-CORE DATA) OVERALL HEIGHT | 0.157 INCHES MINIMUM AND 0.181 INCHES MAXIMUM |
AARH | RELIABILITY FAILURE RATE LEVEL IN PERCENT | 1.000 |
ABJT | TERMINAL LENGTH | 0.200 INCHES MINIMUM AND 0.275 INCHES MAXIMUM |
CWNJ | CAPACITIVE ELECTRODE MATERIAL | TANTALUM |
AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
AAQL | BODY STYLE | W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE |
018-0005-02 | 018-0005-3 | 018-0005-03 | 018 0001 010 |
018-000025 | 018-0005-03 | 018-00001 | 018-0005-01 |
018-0005-02 | 018-000025 | 018-000006 | 018-0005-01 |
018 0005 01 | 018-0005-01 | 018-000025 | 018-0001 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |