Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-307-7134 Item Description: Transformer Power | 5950 | 013077134 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
12353 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 8.250 INCHES NOMINAL |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 6.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 6.500 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 2.500 INCHES NOMINAL |
ABTB | MOUNTING HOLE DIAMETER | 0.218 INCHES MINIMUM SINGLE GROUP AND 0.224 INCHES MAXIMUM SINGLE GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 0.15 KILOVOLT-AMPERE SINGLE COMPONENT |
AGAV | END ITEM IDENTIFICATION | WSD: AIRCRAFT,(AC-130A, AC-130H, MC-130H, EC-130E, HC-130); HERCULE |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 8 SINGLE GROUP |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 30.00 AC POUNDS PER HOUR DRY SINGLE COMPONENT 2ND PRIMARY AND 50.00 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 2ND PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 50.00 AC POUNDS PER HOUR DRY SINGLE COMPONENT 1ST PRIMARY AND 140.00 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 1ST PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 95.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, RECEPTACLE |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
FEAT | SPECIAL FEATURES | WEAPON SYSETM ESSENTIAL |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
123-000-544 | 123-00008 | 123-000011 | 123-000204 |
123-00006 | 123-00067 | 123 000661 | 123-00005 |
123-0-144 | 123-000132 | 123-000132 | 123 000190 |
123-000011 | 123 000 | 123-000011 | 123-0001-000 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote