Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-799-7560 Item Description: Transformer Power A | 5950 | 007997560 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
1007114 A | 1 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.234 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.266 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.891 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 0.985 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 1.906 INCHES MINIMUM AND 1.969 INCHES MAXIMUM |
ADAT | BODY WIDTH | 1.531 INCHES MINIMUM AND 1.594 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 1.718 INCHES MINIMUM AND 1.781 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 105.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY, FIXED AUTOTRANSFORMER TYPE SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 2.25 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
CWJS | WINDING OPERATING VOLTAGE | 60.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY INPUT |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 15 WIRE HOOK |
CWJS | WINDING OPERATING VOLTAGE | 1.80 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY OUTPUT AND 12.84 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY OUTPUT AND 16.28 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY OUTPUT AND 18.53 AC VOLTS NOMINAL SINGLE COMPONENT SIN |
100-0-0019 | 100-00-100 | 100-0 | 100-00-143-007 |
100-0-012 | 100-0 | 100-00-203 | 100-00-143-007 |
100-00-0-035 | 100-0-SS-26-MOD .625 | 100-0-2 | 100 0-3000PSI350 |
100-0-0-3 | 100-00-100 | 100-00-203 | 100-0-2 |