Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5985-01-372-6849 Item Description: Switch Radio Freque | 5985 | 013726849 | 0 | P | B | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | B | A | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
8032-B1237-A1g-7a2 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABKW | OVERALL HEIGHT | 2.250 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 2.250 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.177 INCHES NOMINAL |
AEEA | SWITCH TYPE | NONTRANSFER |
AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 1.800 INCHES NOMINAL SINGLE MOUNTING FACILITY PATTERN |
AHUC | COAXIAL CONNECTOR SERIES DESIGNATION | SMA |
AHUD | CONNECTOR END DESIGN | FEMALE |
AKNF | RF POWER HANDLING CAPABILITY | 1.0 WATTS AVERAGE SINGLE |
AKPC | ACTUATOR OPERATING METHOD | RELAY |
AKPE | ACTUATOR CURRENT TYPE AND RATING IN AMPS | 0.45 DC MAXIMUM |
AKPJ | ACTUATOR VOLTAGE IN VOLTS | 28.0 NOMINAL |
AKPX | POLE QUANTITY | 1 |
AKPY | THROW QUANTITY | 3 |
AKRC | COUPLING POSITION QUANTITY | 12 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
FEAT | SPECIAL FEATURES | WIRES SHALL BE TERMINATED BY STRIPPING OFF 0.5 IN. OF INSULATION AND TINNING THE EXPOSED WIRE; WIRE LENGTH 26 IN. |
TTQY | TERMINAL TYPE AND QUANTITY | 4 PLUG, COAXIAL AND 8 TURRET |
AAQL | BODY STYLE | RECTANGULAR |
ABHP | OVERALL LENGTH | 3.320 INCHES MAXIMUM |
ACZB | III FREQUENCY RATING | 2.2 GIGAHERTZ MINIMUM AND 2.3 GIGAHERTZ MAXIMUM SINGLE FREQUENCY OPERATING |
AFDV | LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 1.800 INCHES NOMINAL SINGLE MOUNTING FACILITY PATTERN |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.20 SINGLE |
AKPP | SWITCHING TIME | 20.0 MILLISECONDS |
AHTX | INSERTION LOSS IN DECIBELS | 0.20 SINGLE |
AKNV | MINIMUM CROSSTALK RATING IN DECIBELS | 60.0 SINGLE |
AKPQ | SWITCH RETURN MECHANISM TYPE | FAIL-SAFE |
CQYJ | MOUNTING FACILITY PATTERN | FOUR POSITION IN-LINE SINGLE MOUNTING FACILITY PATTERN |