MRC | Criteria | Characteristic |
---|---|---|
AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
AAJD | THREAD CLASS | 2B SECOND FLANGE ALL CONNECTION FACILITIES |
AAJF | THREAD DIRECTION | RIGHT-HAND SECOND FLANGE ALL CONNECTION FACILITIES |
ACJL | BEND ANGLE IN DEG | 90.0 ALL BENDS E-PLANE |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |
AHSF | FLANGE QUANTITY | 2 |
AHSX | FLANGE INSIDE WIDTH | 0.620 INCHES MINIMUM FIRST FLANGE AND 0.624 INCHES MAXIMUM FIRST FLANGE |
AHSX | FLANGE INSIDE WIDTH | 0.705 INCHES MINIMUM SECOND FLANGE AND 0.707 INCHES MAXIMUM SECOND FLANGE |
AHSY | FLANGE INSIDE HEIGHT | 0.309 INCHES MINIMUM FIRST FLANGE AND 0.313 INCHES MAXIMUM FIRST FLANGE |
AHSY | FLANGE INSIDE HEIGHT | 0.394 INCHES MINIMUM SECOND FLANGE AND 0.396 INCHES MAXIMUM SECOND FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 1.297 INCHES MINIMUM FIRST FLANGE AND 1.327 INCHES MAXIMUM FIRST FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 1.298 INCHES MINIMUM SECOND FLANGE AND 1.328 INCHES MAXIMUM SECOND FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 1.297 INCHES MINIMUM FIRST FLANGE AND 1.327 INCHES MAXIMUM FIRST FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 1.298 INCHES MINIMUM SECOND FLANGE AND 1.328 INCHES MAXIMUM SECOND FLANGE |
AHTB | FLANGE INSIDE DIAMETER | 0.985 INCHES MINIMUM FIRST FLANGE AND 1.015 INCHES MAXIMUM FIRST FLANGE |
AHTD | FLANGE DEPTH | 0.298 INCHES MINIMUM SECOND FLANGE AND 0.328 INCHES MAXIMUM SECOND FLANGE |
AHTD | FLANGE DEPTH | 0.360 INCHES MINIMUM FIRST FLANGE AND 0.390 INCHES MAXIMUM FIRST FLANGE |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.144 INCHES MINIMUM FIRST FLANGE ALL CONNECTION FACILITIES AND 0.147 INCHES MAXIMUM FIRST FLANGE ALL CONNECTION FACILITIES |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.20 |
AHTX | INSERTION LOSS IN DECIBELS | 0.15 |
CMLP | THREAD QUANTITY PER INCH | 32 SECOND FLANGE ALL CONNECTION FACILITIES |
CQHN | WAVEGUIDE OUTSIDE WIDTH | 0.699 INCHES MINIMUM AND 0.705 INCHES MAXIMUM |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SECOND FLANGE ALL CONNECTION FACILITIES |
CRFH | WAVEGUIDE INSIDE WIDTH | 0.619 INCHES MINIMUM AND 0.624 INCHES MAXIMUM |
CRLB | WAVEGUIDE INSIDE HEIGHT | 0.308 INCHES MINIMUM AND 0.313 INCHES MAXIMUM |
CSFC | WAVEGUIDE OUTSIDE HEIGHT | 0.388 INCHES MINIMUM AND 0.394 INCHES MAXIMUM |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 THREADED HOLE SECOND FLANGE ALL CONNECTION FACILITIES |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE FIRST FLANGE ALL CONNECTION FACILITIES |
CTCJ | FLANGE STYLE | CHOKE TYPE FIRST FLANGE |
CTCJ | FLANGE STYLE | COVER TYPE SECOND FLANGE |
CXBB | WAVEGUIDE CENTER TO CENTER DISTANCE | 7.090 INCHES NOMINAL |
CXBD | WAVEGUIDE HEIGHT | 1.200 INCHES NOMINAL |
FLEX | FLEXIBILITY | RIGID SINGLE TUBING SEGMENT |
MATT | MATERIAL | COPPER ALL FLANGE |
SFTT | SURFACE TREATMENT | ENAMEL ALL FLANGE OUTSIDE SURFACES |
STYL | III STYLE DESIGNATOR | DOUBLE BEND TYPE |
THSD | THREAD SERIES DESIGNATOR | UNC SECOND FLANGE ALL CONNECTION FACILITIES |
ZZZV | FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |
116.000.152 | 116-000.162 | 116-00-000 | 116-000-117 |
116.000.117 | 116.000.146 | 116-000-182 | 116.000.180 |
116-000 | 116-00-25 | 116.000.178 | 116-000-143 |
116-000-162 | 116.000.141 | 116 000 146 | 116 000 141 |