Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-01-406-6943 Item Description: Relay Electromagnet | 5945 | 014066943 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Ms27745-2 | B | 1 | C | A |
MRC | Criteria | Characteristic |
---|---|---|
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
TTQY | TERMINAL TYPE AND QUANTITY | 16 PIN ALL FUNCTIONS |
APNA | WINDING DC RESISTANCE RATING | 405.0 OHMS NOMINAL ALL WINDINGS |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.625 INCHES NOMINAL SINGLE MOUNTING FACILITY |
APNQ | ARC QUENCHING METHOD | AIR |
ABKW | OVERALL HEIGHT | 1.290 INCHES MAXIMUM |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS ALL WINDINGS |
ABTD | MOUNTING SLOT WIDTH | 0.150 INCHES NOMINAL SINGLE MOUNTING FACILITY |
AFJN | III FRAGILITY FACTOR | MODERATELY RUGGED |
CBBL | FEATURES PROVIDED | POLARIZED AND LATCHING CONTACTS |
CSQJ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | 1.396 INCHES MINIMUM SINGLE MOUNTING FACILITY |
SR-1 | SPEC/STD CONTROLLING DATA | |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 75.0 MILLIAMPERES DC ALL WINDINGS |
APCN | COIL QUANTITY | 2 |
CBME | III CUBIC MEASURE | 2.272 CUBIC INCHES |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 4.0 AMPERES AC AND 4.0 AMPERES DC MOTOR LOAD |
APNP | DUTY TYPE | CONTINUOUS |
SR-1 | DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | M83536/18-008L |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-83536/18 GOVERNMENT SPECIFICATION |
ABHP | OVERALL LENGTH | 1.718 INCHES MAXIMUM |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
AKSL | III PURPOSE FOR WHICH DESIGNED | GENERAL |
CQYJ | MOUNTING FACILITY PATTERN | TRIANGLE SINGLE MOUNTING FACILITY |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 3 SLOTTED HOLE SINGLE MOUNTING FACILITY |
CRXH | TIME DELAY | 0.015 SECONDS MAXIMUM FIXED OPERATE TIME |
BBRG | III STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
ABMK | OVERALL WIDTH | 1.025 INCHES MAXIMUM |
FEAT | SPECIAL FEATURES | FAILURE RATE: 3.0 PERCENT PER 10,000 CYCLES |
ADTV | III CASE MATERIAL | METAL |
AKDX | WINDING QUANTITY | 2 |
SR-1 | MANUFACTURERS CODE | 81349 |
SR-1 | NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MIL-PRF-83536 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote