5930-00-543-0839 Item Description: Switch Sensitive | 5930 | 005430839 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
5428 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
SENSITIVE | AAQL | BODY STYLEHOLE MOUNTED |
SENSITIVE | ABFE | HAZARDOUS LOCATIONSENVIRONMENTAL PROTECTIONDUSTPROOF |
SENSITIVE | ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH1 000 INCHES NOMINAL |
SENSITIVE | ADAQ | BODY LENGTH1 938 INCHES NOMINAL |
SENSITIVE | ADAT | BODY WIDTH0 688 INCHES NOMINAL |
SENSITIVE | ADAU | BODY HEIGHT0 921 INCHES NOMINAL |
SENSITIVE | AEBV | UNTHREADED MOUNTING HOLE DIAMETER0 139 INCHES MINIMUM AND 0 142 INCHES MAXIMUM |
SENSITIVE | AFUQ | ACTUATOR STYLEROUND |
SENSITIVE | AFUR | ACTUATOR DIAMETER0 281 INCHES NOMINAL |
SENSITIVE | AFUS | ACTUATOR HEIGHT0 257 INCHES NOMINAL |
SENSITIVE | AFUU | ACTUATOR FREE POSITION HEIGHT0 815 INCHES MINIMUM AND 0 855 INCHES MAXIMUM |
SENSITIVE | AFXE | MAXIMUM VOLTAGE RATING IN VOLTS480 0 AC AND 250 0 DC |
SENSITIVE | AKNA | INCLOSURE TYPEFULLY INCLOSED |
SENSITIVE | AXGY | MOUNTING METHODUNTHREADED HOLE |
SENSITIVE | CBBL | FEATURES PROVIDEDACTUATOR SEAL |
SENSITIVE | CRLD | NONPILE-UP CONTACT ARRANGEMENT1 POLE DOUBLE THROW BOTH POSITIONS MAINTAINED SINGLE SWITCH UNIT |
SENSITIVE | CRRM | SWITCH RELEASE FORCE4 0 OUNCES MINIMUM |
SENSITIVE | CSJN | SWITCH ACTUATING FORCE9 0 OUNCES MINIMUM AND 13 0 OUNCES MAXIMUM |
SENSITIVE | CXQQ | ACTUATOR MOVEMENT0 016 PRETRAVEL INCHES MAXIMUM AND 0 062 OVERTRAVEL INCHES MINIMUM AND 0 0004 DIFFERENTIAL INCHES MINIMUM AND 0 002 DIFFERENTIAL INCHES MAXIMUM |
SENSITIVE | CXQR | CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE250 000 MILLIAMPERES RESISTIVE DC AND 15 000 AMPERES RESISTIVE AC |
SENSITIVE | TTQY | TERMINAL TYPE AND QUANTITY3 SCREW |
542-0-06-13 | 542-0-06-9 | 542-0-06-19 | 542-0-06-9 |
542-0-06-14 | 542-0-06-13 | 542-0-06-14 | 542 0 06 15 |
542-0-06-20 | 542-0-06-19 | 542-0-05-9 | 542-0-06-43 |
542-0-06-42 | 542-0-06-1 | 542-000 | 542-0-06-15 |