Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-485-2000 Item Description: Circuit Breaker | 5925 | 014852000 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
922519 | 5 | 1 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 135.0 ALL LOCATIONS |
ADAQ | BODY LENGTH | 1.562 INCHES MAXIMUM |
ABXD | BUSHING LENGTH | 0.380 INCHES MAXIMUM |
SR-1 | SPEC/STD CONTROLLING DATA | |
AKPX | POLE QUANTITY | 2 |
FREQ | FREQUENCY IN HERTZ | 400.00 ALL LOCATIONS |
FEAT | SPECIAL FEATURES | INCLUDES INSULATING BLOCK FOR SCREW TERMINALS |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC AND 50.0 DC ALL LOCATIONS |
CMLP | THREAD QUANTITY PER INCH | 32 |
SR-1 | DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | M39019/03-215S |
ADTV | CASE MATERIAL | METAL |
ADAT | BODY WIDTH | 1.281 INCHES MAXIMUM |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 300.0 AC AND 500.0 DC ALL LOCATIONS |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 1.0 AMPERES AC AND 1.0 AMPERES DC ALL LOCATIONS |
AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.906 INCHES MAXIMUM |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING W/PANEL SEAL |
CQJX | NOMINAL THREAD SIZE | 0.375 INCHES |
SR-1 | MANUFACTURERS CODE | 81349 |
CPRQ | RESET METHOD | MANUAL |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.594 INCHES MINIMUM AND 0.656 INCHES MAXIMUM |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
TTQY | TERMINAL TYPE AND QUANTITY | 4 SCREW |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.055 MINIMUM AT 200 PCT AND 0.950 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
THSD | THREAD SERIES DESIGNATOR | UNEF |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.950 INCHES MAXIMUM |
SR-1 | NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MIL-PRF-39019/3G |
922-0009-00 | 922-0036-00 | 922-0029-00 | 922-0031-01 |
922-0011-00 | 922 0007 00 | 922-0020-01 | 922-0012-00 |
922-0011-00 | 922-0031-001 | 922 0028 000 | 922-0036-00 |
922-0015-01 | 922 0038 00 | 922 0014 00 | 922-0033-00 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote