MRC | Criteria | Characteristic |
---|---|---|
AAPN | SECTION QUANTITY | 1 |
AAQL | BODY STYLE | CYLINDRICAL SERVO MOUNTED |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AAVL | PILOT DIAMETER | 0.7500 INCHES NOMINAL |
AAVM | PILOT LENGTH | 0.0620 INCHES NOMINAL |
ABHP | OVERALL LENGTH | 2.703 INCHES NOMINAL |
ABPA | UNDERCUT DIAMETER | 0.875 INCHES NOMINAL |
ABPC | UNDERCUT WIDTH | 0.0620 INCHES NOMINAL |
ABPM | BODY DIAMETER | 0.750 INCHES MAXIMUM |
ABWV | SHAFT DIAMETER | 0.1875 INCHES MAXIMUM |
ABXF | SHAFT LENGTH | 0.812 INCHES NOMINAL |
ADAQ | BODY LENGTH | 1.953 INCHES MAXIMUM |
ADAV | OVERALL DIAMETER | 1.200 INCHES MAXIMUM |
AECZ | MOUNTING LIP DIAMETER | 0.8750 INCHES NOMINAL |
AEDA | MOUNTING LIP DEPTH | 0.0620 INCHES NOMINAL |
AEDX | SHAFT STYLE | ROUND |
AEFD | ACTUATOR TYPE | SINGLE SHAFT |
AEFH | EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 3600.0 NOMINAL |
AEFK | MAXIMUM STARTING TORQUE | 1.50 INCH-OUNCES |
AEFL | MAXIMUM RUNNING TORQUE | 1.50 INCH-OUNCES |
AEFM | MAXIMUM STOP TORQUE | 10.00 INCH-OUNCES |
AEFZ | SHAFT RUNOUT | 0.001 INCHES |
AEGA | LATERAL RUNOUT | 0.002 INCHES |
AEGB | PILOT DIAMETER RUNOUT | 0.001 INCHES |
APXH | TERMINAL LOCATION | LONGITUDINALLY POSITIONED ON THE CIRCUMFERENCE |
AXGY | MOUNTING METHOD | CLAMP RING |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 5.0 KILOHMS SINGLE SECTION |
CQCK | ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | 3700.0 MINIMUM |
CQFL | FUNCTION CONFORMITY TOLERANCE PER SECTION | -0.50/+0.50 SINGLE SECTION |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 160.0 SINGLE SECTION |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 1.0 FREE AIR SINGLE SECTION |
CRGM | FUNCTION CONFORMITY PER SECTION | SINGLE SECTION INDEPENDENT LINEARITY |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -10.0/+10.0 SINGLE SECTION |
CRSX | ACTUATOR TRAVEL CONTROL FEATURE | STOPS |
CSBX | FUNCTION CHARACTERISTIC PER SECTION | SINGLE SECTION LINEAR |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 85.0 SINGLE SECTION |
FEAT | SPECIAL FEATURES | 22 IN. MIN LG,NO. 22 AWG WHITE WIRE ATTACHED TO EACH TERMINAL |
TEST | TEST DATA DOCUMENT | 36378-671892 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWI |
TTQY | TERMINAL TYPE AND QUANTITY | 3 TURRET |
09S121-K20S3 | 09S121-S20S3 | 09S130311-1 | 09S1001SU |
09S1001SU | 09S121-K00S3 | 09S121-271S3 | 09S132463-01B |
09S132463 01B | 09S121-S00S3 | 09S101-K015 | 09S130311-1 |
09S101-K013 | 09S132463-01B | 09S12S-000S3 | 09S1001SU |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote