Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5910-01-329-4364 Item Description: Capacitor Variable | 5910 | 013294364 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
300521-141 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | ROTARY |
ABKW | OVERALL HEIGHT | 2.0 MILLIMETERS MAXIMUM |
AEBS | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO DIAMETER | 4.9 MILLIMETERS MINIMUM AND 5.1 MILLIMETERS MAXIMUM |
AECJ | III QUALITY FACTOR AT 25 DEG CELSIUS | 500.0 |
AFWW | TERMINAL WIDTH | 0.2 MILLIMETERS NOMINAL |
AKNA | INCLOSURE TYPE | ENCASED |
AXGR | ADJUSTMENT DEVICE TORQUE | 0.425 INCH-OUNCES MINIMUM AND 1.700 INCH-OUNCES MAXIMUM |
AXGT | III INSULATION DC RESISTANCE AT 25 DEG CELSIUS | 100.0 GIGOHMS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 TERMINAL |
CQJJ | NONDERATED OPERATING TEMP | -25.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
CTGN | CAPACITANCE RANGE IN PICOFARADS | +2.5 TO 5.0 SINGLE SECTION |
CTGP | NONDERATED VOLTAGE RATING AND TYPE | 63.0 DC CONTINUOUS SINGLE SECTION |
CTGQ | CAPACITANCE CHANGE IN PERCENT AT OPERATING TEMP FROM 25 DEG CELSIUS | -4.50 TO 2.00 MINIMUM AND -2.50 TO 2.00 MAXIMUM SINGLE SECTION |
TTQY | TERMINAL TYPE AND QUANTITY | 2 BONDING PAD |
AEBC | TEMP COEFFICIENT OF CAPACITANCE IN PPM PER DEG CELSIUS | 0.0 SINGLE SECTION |
CTGR | ADJUSTMENT DEVICE DRIVE TYPE AND QUANTITY | 1 SLOTTED SCREW |
ADAV | OVERALL DIAMETER | 5.5 MILLIMETERS MINIMUM AND 5.9 MILLIMETERS MAXIMUM |
AGAV | III END ITEM IDENTIFICATION | CALIBRATION STANDARDS EQUIPMENT,YELLOWSTONE CLASS AD-41,GENERAL PURPOSE ELECTRONIC TEST EQUIPMENT |
MATT | III MATERIAL | CERAMIC CAPACITIVE ELECTRODE |
300-0-032768-52031 | 300-00-200 | 300-00 | 300 00 2 5K |
300-00-10K | 300-00-102J | 300-00-102J | 300-0-80X7-32 |
300-0-032768 | 300-00-2K | 300-00-50 | 300-00-1.5K |
300-00-153J | 300 0 125 SS 1 | 300-00-200 | 300-00 |