Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-01-122-4236 Item Description: SWITCH,ROTARY | 5930 | 011224236 | P | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
8900-2 | 5 | 2 | 7 |
MRC | Criteria | Characteristic |
---|---|---|
AAJD | THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
AASA | THREAD LENGTH | 0.312 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DUSTPROOF |
ABHP | OVERALL LENGTH | 4.412 INCHES NOMINAL |
ABNB | FIRST FLAT LENGTH | 0.467 INCHES NOMINAL SINGLE ACTUATOR |
ABNC | FLAT HEIGHT | 0.210 INCHES NOMINAL SINGLE ACTUATOR |
ABWV | SHAFT DIAMETER | 0.250 INCHES NOMINAL SINGLE ACTUATOR |
ABXF | SHAFT LENGTH | 0.500 INCHES NOMINAL SINGLE ACTUATOR |
ADAV | OVERALL DIAMETER | 1.400 INCHES MAXIMUM |
AFBH | INDIVIDUAL SECTION QUANTITY | 6 |
AGAV | END ITEM IDENTIFICATION | 4920-01-054-8585 |
AJZE | SWITCH CONTACT BASIC DESIGN | NONPILE-UP SYMMETRICAL |
AKPX | POLE QUANTITY | 1 EACH SECTION FRONT |
AKPY | THROW QUANTITY | 6 EACH SECTION REAR |
AXGY | MOUNTING METHOD | THREADED BUSHING SINGLE MOUNTING FACILITY |
CQJX | NOMINAL THREAD SIZE | 0.375 INCHES SINGLE MOUNTING FACILITY |
CQMK | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL |
CQMK | CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL |
CQRQ | SHAFT FLAT/SLOT ANGULAR LOCATION | 0.0 DEGREES FROM CONTACT POSITION 1 SINGLE ACTUATOR |
CQTH | ROTOR THROUGH CONNECTION QUANTITY | 1 EACH SECTION |
CRJH | SWITCH ACTUATOR INDEXING POSITION QUANTITY | 6 SINGLE ACTUATOR |
CRSJ | SHAFT TYPE | ROUND, FLATTED SINGLE ACTUATOR |
CSCF | TERMINAL TYPE | TAB, SOLDER LUG |
CSHW | CONTACT SWITCHING ACTION | BREAKS BEFORE MAKES EACH SECTION REAR |
CSLC | SWITCH ACTUATOR POSITIONING INCREMENT | 45.0 DEGREES SINGLE ACTUATOR |
CTDN | SWITCH ACTUATOR STOP DEVICE TYPE | FIXED STOP SINGLE ACTUATOR |
CTHF | CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD AC AT SEA LEVEL |
CTHF | CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD DC AT SEA LEVEL AND 2.5 AMPERES INDUCTIVE LOAD DC AT SEA LEVEL |
STYL | STYLE DESIGNATOR | TAP, CIRCULAR, BUSHING MOUNT |
THSD | THREAD SERIES DESIGNATOR | UNEF SINGLE MOUNTING FACILITY |
890-0005 | 890 001 | 890.002 | 890-001-3 |
890-002 | 890-004-001 | 890-006-001 | 890-0005 |
890-001-3 | 890-005 | 890-0000 | 890-004-001 |
890-001542 | 890-005-001 | 890-003-001 | 890-005-9GPA1-0-B-1-12-JJ |