Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-211-9919 Item Description: Power Supply | 6130 | 012119919 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Dc128 15 60 | 6 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 3.020 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 0.620 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 2.020 INCHES MAXIMUM |
AJJY | DOCUMENT SOURCE | 30635 |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
APNX | INPUT VOLTAGE RATING | 28.0 DC VOLTS NOMINAL SINGLE OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | 12.0 DC VOLTS NOMINAL 2ND POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 15.0 DC VOLTS NOMINAL 1ST POWER OUTPUT |
AYNH | OPERATING AMBIENT TEMP RANGE | -25.0/+71.0 DEG CELSIUS |
BGHX | OUTPUT CONTROL QUANTITY | 1 1ST POWER OUTPUT |
BGHX | OUTPUT CONTROL QUANTITY | 1 2ND POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | FIXED VOLTAGE 1ST POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | FIXED VOLTAGE 2ND POWER OUTPUT |
BHQN | RECTIFICATION METHOD | SINGLE PHASE FULL WAVE CENTER TAP |
CBBL | FEATURES PROVIDED | FILTER |
CWGH | OUTPUT CURRENT RATING | 60.0 DC MILLIAMPERES NOMINAL 1ST POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 60.0 DC MILLIAMPERES NOMINAL 2ND POWER OUTPUT |
CWGZ | RIPPLE VOLTAGE AT FULL LOAD | 11.0 MILLIVOLTS AVERAGE 1ST POWER OUTPUT |
CWGZ | RIPPLE VOLTAGE AT FULL LOAD | 11.0 MILLIVOLTS AVERAGE 2ND POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 2 1ST POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 2 2ND POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | WIRE LEAD 1ST POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | WIRE LEAD 2ND POWER OUTPUT |
CWHM | INPUT CURRENT RATING | 20.0 DC MILLIAMPERES MINIMUM SINGLE OPERATING POWER RQMT AND 120.0 DC MILLIAMPERES MAXIMUM SINGLE OPERATING POWER RQMT |
CWHQ | INPUT CONNECTION TYPE | WIRE LEAD SINGLE OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 2 SINGLE OPERATING POWER RQMT |
CWKG | VENTILATION DESIGN TYPE | CONVECTION |
ZZZV | FSC APPLICATION DATA | TEST SET ELECTRICAL EQUIPMENT |
DC1-00148 | DC1-00136-001 | DC1-00150 | DC1-00204-1 |
DC1-00136 | DC1-00137 | DC1-00138-001 | DC1-02 |
DC1-00137-001 | DC1-00150-001 | DC1-00206-001 | DC1-00138 |
DC1-00215-001 | DC1-00204-001 | DC1-00149-001 | DC1-00206 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote