Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-00-857-2454 Item Description: Relay Electromagnet | 5945 | 008572454 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | G | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Ms25329-D1 | 1 | 2 | 2 |
MRC | Criteria | Characteristic |
---|---|---|
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC RESISTIVE LOAD AND 5.0 AMPERES DC RESISTIVE LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 800.0 MILLIAMPERES AC LAMP LOAD AND 800.0 MILLIAMPERES DC LAMP LOAD |
PRMT | PRECIOUS MATERIAL | GOLD |
TTQY | TERMINAL TYPE AND QUANTITY | 20 PIN ALL FUNCTIONS |
ABHP | OVERALL LENGTH | 2.187 INCHES MAXIMUM |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.750 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABMK | OVERALL WIDTH | 1.531 INCHES MAXIMUM |
ADTV | CASE MATERIAL | METAL |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.147 INCHES NOMINAL SINGLE MOUNTING FACILITY |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AKDX | WINDING QUANTITY | 1 |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
APNP | DUTY TYPE | CONTINUOUS |
APNQ | ARC QUENCHING METHOD | AIR |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CBME | III CUBIC MEASURE | 7.218 CUBIC INCHES |
CQYJ | MOUNTING FACILITY PATTERN | TRIANGLE SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 6 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CRXH | TIME DELAY | 0.02 SECONDS MAXIMUM FIXED RELEASE TIME |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.5 AMPERES AC MOTOR LOAD AND 1.5 AMPERES DC MOTOR LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 3.0 AMPERES AC INDUCTIVE LOAD AND 3.0 AMPERES DC INDUCTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
PMLC | PRECIOUS MATERIAL AND LOCATION | TERMINAL SURFACES GOLD |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-6106 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTIN |
ZZZK | SPECIFICATION/STANDARD DATA | 96906-MS25329 GOVERNMENT STANDARD |
ABKW | OVERALL HEIGHT | 2.156 INCHES NOMINAL |
APCN | COIL QUANTITY | 1 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 3 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
CRXH | TIME DELAY | 0.025 SECONDS MAXIMUM FIXED OPERATE TIME |
CSQJ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | 1.844 INCHES NOMINAL SINGLE MOUNTING FACILITY |