5945-01-276-2310 Item Description: Relay Electromagnet | 5945 | 012762310 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
907-36c-12 | 5 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAJD | THREAD CLASS | 2B SINGLE MOUNTING FACILITY |
AAJF | THREAD DIRECTION | RIGHT-HAND SINGLE MOUNTING FACILITY |
ABHP | OVERALL LENGTH | 3.125 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.375 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 3.250 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 1.031 INCHES MAXIMUM |
ADTV | CASE MATERIAL | PLASTIC |
ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AGAV | END ITEM IDENTIFICATION | B52C130F16SIM |
AKDX | WINDING QUANTITY | 2 |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
APCN | COIL QUANTITY | 2 |
APNP | DUTY TYPE | CONTINUOUS |
APNQ | ARC QUENCHING METHOD | AIR |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE SINGLE MOUNTING FACILITY |
AYSC | PILE-UP MAIN CONTACT FORM ARRANGEMENT | 36C |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CBBL | FEATURES PROVIDED | LATCHING CONTACTS |
CBME | III CUBIC MEASURE | 10.471 CUBIC INCHES |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE MOUNTING FACILITY |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
CRXH | TIME DELAY | 0.004 SECONDS NOMINAL FIXED RELEASE TIME |
CRXH | TIME DELAY | 0.015 SECONDS NOMINAL FIXED OPERATE TIME |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 12.0 VOLTS DC 25 DEG CELSIUS ALL WINDINGS |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 125.0 MILLIAMPERES AC RESISTIVE LOAD AND 1.0 AMPERES DC RESISTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 120.0 AC AND 28.0 DC |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
TTQY | TERMINAL TYPE AND QUANTITY | 112 TAB, SOLDER LUG ALL FUNCTIONS |
907-003-NF11-P2 | 907-003-NF17-P1 | 907-003-NF15-S1 | 907-010 |
907-0034 | 907-001NF25-1S | 907-0.105 | 907-003-NF11-P1 |
907-001NF25-1P | 907-00 | 907-0008 | 907 010 |
907-0008 | 907-0.105 | 907-0010 | 907-0010 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote