5945-01-065-5793 Item Description: Relay Electromagnet | 5945 | 010655793 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | C | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
931-48cg-24 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 2.718 INCHES MINIMUM AND 2.781 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.343 INCHES MINIMUM FIRST MOUNTING FACILITY AND 2.406 INCHES MAXIMUM FIRST MOUNTING FACILITY |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.343 INCHES MINIMUM SECOND MOUNTING FACILITY AND 2.406 INCHES MAXIMUM SECOND MOUNTING FACILITY |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.405 INCHES MINIMUM FIRST MOUNTING FACILITY AND 0.468 INCHES MAXIMUM FIRST MOUNTING FACILITY |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.405 INCHES MINIMUM SECOND MOUNTING FACILITY AND 0.468 INCHES MAXIMUM SECOND MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 3.968 INCHES MINIMUM AND 4.031 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 1.514 INCHES MINIMUM AND 1.577 INCHES MAXIMUM |
ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.138 INCHES NOMINAL FIRST MOUNTING FACILITY |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.138 INCHES NOMINAL SECOND MOUNTING FACILITY |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AFRG | CONTACT MATERIAL | SILVER |
AKDX | WINDING QUANTITY | 1 |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
APCN | COIL QUANTITY | 1 |
APNA | WINDING DC RESISTANCE RATING | 394.2 OHMS MINIMUM SINGLE WINDING AND 481.8 OHMS MAXIMUM SINGLE WINDING |
APNP | DUTY TYPE | CONTINUOUS |
APNQ | ARC QUENCHING METHOD | AIR |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 6 UNTHREADED HOLE FIRST MOUNTING FACILITY |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 6 UNTHREADED HOLE SECOND MOUNTING FACILITY |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CBME | III CUBIC MEASURE | 17.015 CUBIC INCHES |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR FIRST MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SECOND MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 48 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CRXH | TIME DELAY | 0.005 SECONDS MAXIMUM FIXED RELEASE TIME |
CRXH | TIME DELAY | 0.035 SECONDS MAXIMUM FIXED OPERATE TIME |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 24.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 333.0 MILLIAMPERES AC RESISTIVE LOAD AND 1.0 AMPERES DC RESISTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 120.0 AC AND 28.0 DC |
PMLC | PRECIOUS MATERIAL AND LOCATION | CONTACT SURFACES GOLD AND CONTACT SURFACES RHODIUM AND CONTACTS SILVER |
PRMT | PRECIOUS MATERIAL | GOLD AND RHODIUM AND SILVER |
TTQY | TERMINAL TYPE AND QUANTITY | 146 TAB, SOLDER LUG ALL FUNCTIONS |
931-0034-000 | 931-0036-00 | 931-0033 | 931-0036-00 |
931-0-50AMPDC | 931-0-50AMPDC | 931-0034-000 | 931-0-50DCV |
931-0033 | 931-0-10ADC | 931-0-10DCA | 931-0-50DCV |
931-0033 | 931-0-10DCA | 931-0036-00 | 931 00 |