Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5955-01-008-5870 Item Description: Crystal Unit Quartz | 5955 | 010085870 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
7 | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Cr-65 U | 2 | 1 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 1.023 INCHES MAXIMUM |
ABJT | TERMINAL LENGTH | 0.223 INCHES MINIMUM AND 0.248 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 0.757 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 0.775 INCHES MAXIMUM |
ADAT | BODY WIDTH | 0.725 INCHES MAXIMUM |
ADPR | BODY THICKNESS | 0.317 INCHES MAXIMUM |
ADUM | OVERALL THICKNESS | 0.352 INCHES MAXIMUM |
AEBT | TERMINAL DIAMETER | 0.048 INCHES MINIMUM AND 0.052 INCHES MAXIMUM |
AEHC | III MODE OF OSCILLATION | THIRD OVERTONE |
AEHD | CIRCUIT RESONANCE | SERIES RESONANCE |
AEHF | SHUNT CAPACITANCE IN PICOFARADS | 7.0 MAXIMUM |
AEHG | SPECIFIED FREQUENCY | 42.066667 MEGAHERTZ |
AEHK | FREQUENCY TOLERANCE AT REFERENCE TEMP IN PERCENT | -0.001/+0.001 |
AEHL | FREQUENCY STABILITY IN PERCENT | -0.00025/+0.00025 |
AEHM | CONTROLLED REFERENCE TEMP | 75.0 DEG CELSIUS |
AEHN | OPERABLE TEMP RANGE | -55.0/+90.0 DEG CELSIUS |
AEHS | HOLDER COVER MATERIAL | METAL |
AFGA | OPERATING TEMP RANGE | +70.0/+80.0 DEG CELSIUS |
CQBK | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.478 NOMINAL MILS AND 0.494 NOMINAL CENTIMETERS |
CQYL | DRIVE LEVEL RATING | 0.8 MILLIWATTS MINIMUM AND 1.2 MILLIWATTS MAXIMUM |
CRFX | FREQUENCY TOLERANCE FOR OPERATING TEMP IN PERCENT | -0.001/+0.001 |
CRMP | EQUIVALENT RESISTANCE VALUE IN OHMS | 40.0 MAXIMUM |
STYL | STYLE DESIGNATOR | OVAL BODY, PIN TERMINALS |
TEST | TEST DATA DOCUMENT | 81349-MILC3098 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MILC3098/43 GOVERNMENT SPECIFICATION |
CR-0001-00 | CR-0079 | CR-0065 | CR-0065 |
CR-00028-009 | CR-00028-008 | CR-00011-001 | CR-00028-010 |
CR-004A | CR-0038 | CR-0002-00 | CR-00028-006 |
CR-0034 | CR-00028-004 | CR-00028-007 | CR-002A |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |