Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5910-01-393-0002 Item Description: Capacitor Fixed Ele | 5910 | 013930002 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
86-00039-010 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AEBT | TERMINAL DIAMETER | 0.024 INCHES NOMINAL |
AECE | III ANODE TYPE | SOLID |
ABHP | (NON-CORE DATA) OVERALL LENGTH | 1.535 INCHES NOMINAL |
AECQ | ELECTRICAL POLARIZATION | POLARIZED |
ABKW | (NON-CORE DATA) OVERALL HEIGHT | 0.492 INCHES NOMINAL |
CRTP | TOLERANCE RANGE PER SECTION | -20.00 TO 20.00 PERCENT SINGLE SECTION |
CQJJ | NONDERATED OPERATING TEMP | -40.0 DEG CELSIUS MINIMUM AND 105.0 DEG CELSIUS MAXIMUM |
ABMK | (NON-CORE DATA) OVERALL WIDTH | 0.492 INCHES NOMINAL |
CWPM | DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 0.080 |
CWQC | EQUIVALENT SERIES RESISTANCE AT REFERENCE TEMP IN OHMS | 1.10 |
CWJK | CASE MATERIAL | METAL |
ABPM | BODY DIAMETER | 0.492 INCHES NOMINAL |
TTQY | TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
CQBQ | CAPACITANCE VALUE PER SECTION | 100.000 MICROFARADS SINGLE SECTION |
CWQH | DC LEAKAGE AT REFERENCE TEMP | 20.000 MICROAMPERES |
CWQQ | REFERENCE TEMP AT WHICH RATED | 25.0 DEG CELSIUS |
AEBS | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO DIAMETER | 0.197 INCHES NOMINAL |
CWSG | III TERMINAL SURFACE TREATMENT | SOLDER |
CWNJ | CAPACITIVE ELECTRODE MATERIAL | ALUMINUM |
ADAQ | BODY LENGTH | 0.787 INCHES NOMINAL |
CWSZ | CASE INSULATION MATERIAL | PLASTIC |
AAQL | BODY STYLE | W/O MTG FACILITIES, TERMINAL(S) ON ONE END |
ABJT | TERMINAL LENGTH | 0.591 INCHES MINIMUM AND 0.748 INCHES MAXIMUM |
CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 100.0 DC SINGLE SECTION |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
86-00013-090 | 86-00004-001 | 86-0003 | 86-00-0-240-0000 |
86-00007-001 | 86-00042-001 | 86-00007-001 | 86-00040-000 |
86-00025-010 | 86-00013-090 | 86-000 | 86-0000 |
86-00004-001 | 86-00042-001 | 86-00013-090 | 86-00025-010 |