5910-01-342-2802 Item Description: Capacitor Variable | 5910 | 013422802 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | S | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
03-3079 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | ROTARY |
ABJT | TERMINAL LENGTH | 0.250 INCHES MINIMUM AND 0.280 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 0.140 INCHES MINIMUM AND 0.180 INCHES MAXIMUM |
AECJ | III QUALITY FACTOR AT 25 DEG CELSIUS | 500.0 |
AFWW | TERMINAL WIDTH | 0.040 INCHES NOMINAL |
AFWY | TERMINAL THICKNESS | 0.008 INCHES NOMINAL |
AGAV | III END ITEM IDENTIFICATION | 6625-01-258-2893 TESTER,SEMICOND |
AKNA | INCLOSURE TYPE | ENCASED |
AXGR | ADJUSTMENT DEVICE TORQUE | 0.500 INCH-OUNCES MINIMUM AND 3.000 INCH-OUNCES MAXIMUM |
CQJJ | NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM |
CTGN | CAPACITANCE RANGE IN PICOFARADS | +3.0 TO 15.0 SINGLE SECTION |
CTGQ | CAPACITANCE CHANGE IN PERCENT AT OPERATING TEMP FROM 25 DEG CELSIUS | -4.50 TO 2.00 MINIMUM AND -4.20 TO 3.40 MAXIMUM SINGLE SECTION |
MATT | III MATERIAL | CERAMIC CAPACITIVE ELECTRODE |
PMLC | III PRECIOUS MATERIAL AND LOCATION | ALL METAL SURFACES SILVER |
PRMT | III PRECIOUS MATERIAL | SILVER |
TTQY | TERMINAL TYPE AND QUANTITY | 2 PRINTED CIRCUIT |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 TERMINAL |
ADAV | OVERALL DIAMETER | 0.208 INCHES MINIMUM AND 0.228 INCHES MAXIMUM |
AEBS | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO DIAMETER | 0.197 INCHES MINIMUM AND 0.203 INCHES MAXIMUM |
CTGP | NONDERATED VOLTAGE RATING AND TYPE | 100.0 DC CONTINUOUS SINGLE SECTION |
CTGR | ADJUSTMENT DEVICE DRIVE TYPE AND QUANTITY | 1 SLOTTED SCREW |
03 00 01 14 | 03-00-0002 | 03-000-0018 | 03-000-01 |
03 00 182 | 03-00-0002 | 03-0-15-205-0FL | 03-000-0001 |
03 00 041 | 03-00.02.13 | 03-000-0016 | 03-000-0001 |
03 00 AK | 03-000-0001 | 03-0-15-150-0-FL | 03-00-0002 |