Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5962-01-346-8845 Item Description: Microcircuit Memory | 5962 | 013468845 | 0 | N | D | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | D | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
84036 | 5 | 1 | 4 |
MRC | Criteria | Characteristic |
---|---|---|
ABKW | OVERALL HEIGHT | 0.400 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 0.290 INCHES MINIMUM AND 0.320 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 1.280 INCHES MAXIMUM |
ADAT | BODY WIDTH | 0.220 INCHES MINIMUM AND 0.310 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 0.185 INCHES MAXIMUM |
AEHX | MAXIMUM POWER DISSIPATION RATING | 1.0 WATTS |
AFGA | OPERATING TEMP RANGE | -55.0 TO 125.0 DEG CELSIUS |
AFJQ | STORAGE TEMP RANGE | -55.0 TO 150.0 DEG CELSIUS |
CBBL | FEATURES PROVIDED | BURN IN AND ELECTROSTATIC SENSITIVE AND MONOLITHIC AND PROGRAMMABLE AND STATIC OPERATION |
CQSJ | INCLOSURE MATERIAL | CERAMIC |
CQSZ | INCLOSURE CONFIGURATION | DUAL-IN-LINE |
CQWX | OUTPUT LOGIC FORM | COMPLEMENTARY-METAL OXIDE-SEMICONDUCTOR LOGIC |
CQZP | INPUT CIRCUIT PATTERN | 12 INPUT |
CTFT | CASE OUTLINE SOURCE AND DESIGNATOR | D-9 MIL-M-38510 |
CWSG | TERMINAL SURFACE TREATMENT | SOLDER |
CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | MICROCIRCUITS,MEMORY DIGITAL STATIC RAM |
CZEN | VOLTAGE RATING AND TYPE PER CHARACTERISTIC | 0.3 VOLTS MINIMUM POWER SOURCE AND 7.0 VOLTS MAXIMUM POWER SOURCE |
CZEQ | TIME RATING PER CHACTERISTIC | 45.00 NANOSECONDS MAXIMUM ACCESS |
CZER | MEMORY DEVICE TYPE | RAM |
TEST | TEST DATA DOCUMENT | 96906-MIL-STD-883 STANDARD (INCLUDES INDUSTRY OR ASSOCIATION STANDARDS, INDIVIDUAL MANUFACTUREER STANDARDS, ETC.). |
TTQY | TERMINAL TYPE AND QUANTITY | 24 PRINTED CIRCUIT |
CTQX | CURRENT RATING PER CHARACTERISTIC | 85.00 MILLIAMPERES MAXIMUM SUPPLY |
840-0016-03087 | 840-00005 | 840-00005 | 840-002-001 |
840-002-001 | 840-000168-300 | 840-001 | 840-0033 |
840-0034 | 840-003-001 | 840-0000 | 840-0016-03087 |
840-003-001 | 840-0033 | 840-000270-000 | 840-000270-000 |