NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-182-3759 Item Description: Transformer Assembl | 5950 | 011823759 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
10064340-101 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHY | TURN QUANTITY | 228 ALL COMPONENTS SINGLE SECONDARY |
ABHY | TURN QUANTITY | 690 1ST COMPONENT SINGLE PRIMARY |
ABHY | TURN QUANTITY | 690 2ND COMPONENT 1ST PRIMARY |
ABHY | TURN QUANTITY | 690 3RD COMPONENT SINGLE PRIMARY |
ABHY | TURN QUANTITY | 744 2ND COMPONENT 2ND PRIMARY |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL ALL COMPONENTS |
ACZX | WINDING SHIELDING METHOD | CORE GROUNDED AND BROUGHT OUT TO TERMINAL 2ND COMPONENT AND INTERNAL SHIELD BROUGHT OUT TO TERMINAL 2ND COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL 1ST COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL 3RD COMPONENT |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AXGY | MOUNTING METHOD | TERMINAL SINGLE GROUP |
BKPL | RATING METHOD | WINDING TURNS SINGLE COMPONENT SINGLE WINDING |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 1ST COMPONENT AND 1 SECONDARY 1ST COMPONENT |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 3RD COMPONENT AND 1 SECONDARY 3RD COMPONENT |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY 2ND COMPONENT AND 1 SECONDARY 2ND COMPONENT |
CQPZ | WINDING CONDUCTOR SIZE | 0.00445 INCHES AMERICAN WIRE GAGE 2ND COMPONENT 2ND PRIMARY |
CQPZ | WINDING CONDUCTOR SIZE | 0.01264 INCHES AMERICAN WIRE GAGE 1ST COMPONENT SINGLE PRIMARY |
CQPZ | WINDING CONDUCTOR SIZE | 0.01264 INCHES AMERICAN WIRE GAGE 2ND COMPONENT 1ST PRIMARY |
CQPZ | WINDING CONDUCTOR SIZE | 0.01264 INCHES AMERICAN WIRE GAGE 3RD COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 199.20 AC VOLTS NOMINAL 1ST COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 199.20 AC VOLTS NOMINAL 2ND COMPONENT 1ST PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 199.20 AC VOLTS NOMINAL 3RD COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 214.80 AC VOLTS NOMINAL 2ND COMPONENT 2ND PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 65.80 AC VOLTS NOMINAL ALL COMPONENTS SINGLE SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 18 WIRE LEAD |
100-00-100 | 100-00-100 | 100-00-0-035 | 100-0 |
100-0-2 | 100-0-2 | 100-0-012 | 100-0-2 |
100-00-0-035 | 100-0-SS-26-MOD .625 | 100-00-203 | 100-00-143-007 |
100-0-0-3 | 100-0-0019 | 100-00-203 | 100-00-143-007 |