Note : We Will Not Share Your Information To Any Third Parties.
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 6.000 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 5.250 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 3.875 INCHES NOMINAL |
ADAQ | BODY LENGTH | 4.250 INCHES NOMINAL |
ADAU | BODY HEIGHT | 4.000 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.200 INCHES NOMINAL |
AEVT | CAPILLARY TUBE LENGTH | 42.000 INCHES NOMINAL |
AEVU | BULB LENGTH | 2.500 INCHES NOMINAL |
AEVV | BULB DIAMETER | 2.500 INCHES NOMINAL |
AJZC | PRESSURE SWITCH TYPE | ABSOLUTE |
AKBY | TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB |
AXGY | MOUNTING METHOD | UNTHREADED HOLE |
CQGB | CONTACT ACTION STIMULUS | DECREASE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 3 POLE, DOUBLE THROW, THREE POSITIONS MAINTAINED |
CSCF | TERMINAL TYPE | TAB W/SCREW |
CTHF | CONTACT LOAD CURRENT RATING | 10.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD FOURTH VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 7.5 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE |
CTYM | CONTACT ADJUSTMENT RANGE | +10.00/+70.00 ACTUATION POINT POUNDS PER SQUARE INCH |
CTYS | CONTACT ADJUSTMENT TYPE | INTERNAL ACTUATION POINT SHAFT |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 12.0 DC AT SEA LEVEL FOURTH VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 120.0 AC AT SEA LEVEL FIRST VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 240.0 AC AT SEA LEVEL SECOND VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 6.0 DC AT SEA LEVEL THIRD VOLTAGE |
FREQ | FREQUENCY IN HERTZ | 60.0 FIRST VOLTAGE |
FREQ | FREQUENCY IN HERTZ | 60.0 SECOND VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | LIQUID |
STYL | III STYLE DESIGNATOR | RECTANGULAR W/MOUNTING LUGS |
200-0-2-10 | 200-0.50 NPT | 200-0-10IN | 200-0-0-0-0-0-0-0 |
200-0-10IN | 200-0 600PSI | 200-00-5K | 200-00-501J |
200-0 600PSI | 200-00-103J | 200-0-2-10 | 200 00 202J |
200-00-103J | 200-0-2-10 | 200-00-10K | 200-0-65WC0-100 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote