NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5905-00-247-2384 Item Description: Resistor Thermal | 5905 | 002472384 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
912102-3 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 0.422 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0.260 INCHES NOMINAL |
ADAV | OVERALL DIAMETER | 0.250 INCHES NOMINAL |
AEBT | TERMINAL DIAMETER | 0.03196 INCHES NOMINAL |
AEHX | MAXIMUM POWER DISSIPATION RATING | 5.00 MILLIWATTS |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 25.0 DEG CELSIUS |
AEHZ | MAXIMUM OPERATING TEMP | 105.0 DEG CELSIUS |
AEJA | THERMAL TIME CONSTANT IN SECONDS | 3.0 |
AEJB | POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 3.0 |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 63.9 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 19.8 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -5.0/+5.0 ALL RESISTANCE-TEMPERATURE POINTS |
AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
AKNA | INCLOSURE TYPE | ENCASED |
CGGK | MOUNTING THREAD QUANTITY | 32 PER INCH |
CQWD | III ZERO POWER RESISTANCE | 94.000 KILOHMS |
CRQJ | ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -2.0 TO 2.0 |
CRYY | MOUNTING FACILITY NOMINAL SCREW THREAD DIAMETER | 0.164 INCHES |
STYL | STYLE DESIGNATOR | SCREW MOUNTED |
TEST | TEST DATA DOCUMENT | 06481-912102 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWI |
TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
912-0004-00 | 912-0006 | 912-0008 | 912-0005-01 |
912-00-008 | 912-0010-02 | 912-0011 | 912 00 008 |
912-0009 | 912-0010 | 912-0005 | 912-0006-01 |
912-0009-02 | 912-0004 | 912-0007 | 912-0004-01 |