Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5905-00-056-4295 Item Description: Resistor Variable N | 5905 | 000564295 | 0 | N | B | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | B | U | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
116fts259 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAPN | SECTION QUANTITY | 11 |
AAQL | BODY STYLE | CYLINDRICAL SERVO MOUNTED |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AAVL | PILOT DIAMETER | 0.9688 INCHES NOMINAL |
AAVM | PILOT LENGTH | 0.6200 INCHES NOMINAL |
ABNB | FIRST FLAT LENGTH | 0.375 INCHES NOMINAL |
ABNC | FLAT HEIGHT | 0.105 INCHES NOMINAL |
ABPA | UNDERCUT DIAMETER | 0.968 INCHES NOMINAL |
ABPC | UNDERCUT WIDTH | 0.0570 INCHES MINIMUM |
ABPM | BODY DIAMETER | 1.062 INCHES NOMINAL |
ABWV | SHAFT DIAMETER | 0.1247 INCHES NOMINAL |
ABXF | SHAFT LENGTH | 0.437 INCHES NOMINAL |
ADAQ | BODY LENGTH | 2.680 INCHES NOMINAL |
AECZ | MOUNTING LIP DIAMETER | 1.0750 INCHES MAXIMUM |
AEDA | MOUNTING LIP DEPTH | 0.0620 INCHES NOMINAL |
AEDX | SHAFT STYLE | ROUND, FLATTED |
AEDZ | SHAFT BEARING TYPE | BALL |
AEFD | ACTUATOR TYPE | SINGLE SHAFT |
AEFH | EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 340.0 NOMINAL |
AEFK | MAXIMUM STARTING TORQUE | 3.45 INCH-OUNCES |
AEFL | MAXIMUM RUNNING TORQUE | 3.45 INCH-OUNCES |
AEFM | MAXIMUM STOP TORQUE | 32.00 INCH-OUNCES |
AEFY | SHAFT END PLAY | 0.005 INCHES |
AEFZ | SHAFT RUNOUT | 0.002 INCHES |
AEGA | LATERAL RUNOUT | 0.001 INCHES |
AEGB | PILOT DIAMETER RUNOUT | 0.001 INCHES |
AEGC | SHAFT RADIAL PLAY | 0.001 INCHES |
APXH | TERMINAL LOCATION | RADIALLY POSITIONED OVER MORE THAN HALF THE CIRCUMFERENCE |
AXGY | MOUNTING METHOD | CLAMP RING |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 10.0 PERCENT, RATED AMPERES C AND BETTER FINISH |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 2.0 PERCENT, RATED AMPERES C SELECT |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 20.0 KILOHMS 6TH SECTION |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 20.0 KILOHMS 8TH SECTION |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 20.0 PERCENT, RATED AMPERES C DROP SIDING |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 20.0 PERCENT, RATED AMPERES C FLOORING |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 30.0 KILOHMS 10TH SECTION |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 30.0 PERCENT, RATED AMPERES C AND BETTER SELECT |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 30.0 PERCENT, RATED AMPERES FOUNDATION |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 7.5 KILOHMS 2ND SECTION |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 7.5 KILOHMS 4TH SECTION |
CQCH | TAP LOCATION FROM CCW TERMINAL PER SECTION IN DEG OF EFFECTIVE ELECTRICAL ROTATION | 156.36 5TH SECTION |
CQCH | TAP LOCATION FROM CCW TERMINAL PER SECTION IN DEG OF EFFECTIVE ELECTRICAL ROTATION | 156.36 6TH SECTION AND 232.72 6TH SECTION |
CQCH | TAP LOCATION FROM CCW TERMINAL PER SECTION IN DEG OF EFFECTIVE ELECTRICAL ROTATION | 156.36 7TH SECTION |
CQCH | TAP LOCATION FROM CCW TERMINAL PER SECTION IN DEG OF EFFECTIVE ELECTRICAL ROTATION | 156.36 8TH SECTION AND 232.72 8TH SECTION |
CQCH | TAP LOCATION FROM CCW TERMINAL PER SECTION IN DEG OF EFFECTIVE ELECTRICAL ROTATION | 38.17 2ND SECTION AND 87.27 2ND SECTION AND 136.37 2ND SECTION |
CQCH | TAP LOCATION FROM CCW TERMINAL PER SECTION IN DEG OF EFFECTIVE ELECTRICAL ROTATION | 38.17 4TH SECTION AND 87.27 4TH SECTION AND 136.37 4TH SECTION |
CQCK | ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | 360.0 NOMINAL |
CQFL | FUNCTION CONFORMITY TOLERANCE PER SECTION | -0.25 TO 0.25 1ST SECTION |
CQFL | FUNCTION CONFORMITY TOLERANCE PER SECTION | -0.30/+0.30 11TH SECTION |
CQFL | FUNCTION CONFORMITY TOLERANCE PER SECTION | -0.65 TO 0.65 10TH SECTION |
CQFL | FUNCTION CONFORMITY TOLERANCE PER SECTION | -0.65 TO 0.65 3RD SECTION |
CQFL | FUNCTION CONFORMITY TOLERANCE PER SECTION | -1.00/+1.00 2ND SECTION |
CQFL | FUNCTION CONFORMITY TOLERANCE PER SECTION | -1.00/+1.00 4TH SECTION |
CQFL | FUNCTION CONFORMITY TOLERANCE PER SECTION | -1.50 TO 1.50 5TH SECTION |
CQFL | FUNCTION CONFORMITY TOLERANCE PER SECTION | -1.50 TO 1.50 8TH SECTION |
CQFL | FUNCTION CONFORMITY TOLERANCE PER SECTION | -1.50/+1.50 6TH SECTION |
CQFL | FUNCTION CONFORMITY TOLERANCE PER SECTION | -1.50/+1.50 7TH SECTION |
CQFL | FUNCTION CONFORMITY TOLERANCE PER SECTION | -2.00/+2.00 9TH SECTION |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 100.0 ALL SECTIONS |
CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -400.0/+400.0 ALL SECTIONS |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 1.0 FREE AIR ALL SECTIONS |
CRGM | FUNCTION CONFORMITY PER SECTION | ALL SECTIONS ABSOLUTE CONFORMITY |
CRJS | FIXED TAP QUANTITY PER SECTION | 1 5TH SECTION |
CRJS | FIXED TAP QUANTITY PER SECTION | 1 7TH SECTION |
CRJS | FIXED TAP QUANTITY PER SECTION | 2 6TH SECTION |
CRJS | FIXED TAP QUANTITY PER SECTION | 2 8TH SECTION |
CRJS | FIXED TAP QUANTITY PER SECTION | 3 2ND SECTION |
CRJS | FIXED TAP QUANTITY PER SECTION | 3 4TH SECTION |
CRKS | TAP LOCATION TOLERANCE PER SECTION | -2.0 TO 2.0 DEG ANGULAR ROTATION ALL SECTIONS |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -10.0/+10.0 ALL SECTIONS |
CRSX | ACTUATOR TRAVEL CONTROL FEATURE | CONTINUOUS MOTION |
CSBX | FUNCTION CHARACTERISTIC PER SECTION | ALL SECTIONS EQUATION |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 25.0 ALL SECTIONS |
TEST | TEST DATA DOCUMENT | 97942-577R900 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAW |
TTQY | TERMINAL TYPE AND QUANTITY | 45 TURRET |
116 000 157 | 116-000-143 | 116-000-182 | 116.000.146 |
116 000 141 | 116-000 | 116-000.162 | 116-000-162 |
116-00-25 | 116.000.180 | 116-000-117 | 116-000 |
116.000.143 | 116.000.152 | 116 000 146 | 116-000-157 |