Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5915-00-995-4759 Item Description: Filter Band Pass | 5915 | 009954759 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
7 | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
20-0195-00 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABKW | OVERALL HEIGHT | 5.950 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 6.500 INCHES MAXIMUM |
ADAT | BODY WIDTH | 5.750 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 5.250 INCHES MAXIMUM |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 5.375 INCHES NOMINAL |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 4.625 INCHES NOMINAL |
AFGA | OPERATING TEMP RANGE | +15.0/+55.0 DEG CELSIUS |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 260.0 SINGLE HIGH PASS PULSES PER SECOND |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 270.0 SINGLE HIGH PASS TWO PHASE TO TWO PHASE |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 280.0 SINGLE HIGH PASS TWO PHASE TO THREE PHASE |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 290.0 SINGLE HIGH PASS HERTZ |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 300.0 SINGLE HIGH PASS THREE PHASE TO TWO PHASE |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 310.0 SINGLE HIGH PASS GIGAHERTZ |
AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 600.0 OHMS 1ST BAND PASS |
AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 600.0 OHMS 2ND BAND PASS |
AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 600.0 OHMS 3RD BAND PASS |
AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 600.0 OHMS 4TH BAND PASS |
AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 600.0 OHMS 5TH BAND PASS |
AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 600.0 OHMS 6TH BAND PASS |
AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 34.0 KILOHMS 1ST BAND PASS |
AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 34.0 KILOHMS 2ND BAND PASS |
AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 34.0 KILOHMS 3RD BAND PASS |
AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 34.0 KILOHMS 4TH BAND PASS |
AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 34.0 KILOHMS 5TH BAND PASS |
AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 34.0 KILOHMS 6TH BAND PASS |
AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
AKNA | INCLOSURE TYPE | ENCASED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED STUD |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 22.5 1ST BAND PASS |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 22.5 2ND BAND PASS |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 22.5 3RD BAND PASS |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 22.5 4TH BAND PASS |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 22.5 5TH BAND PASS |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 22.5 6TH BAND PASS |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 TAB, SOLDER LUG GROUND 3RD FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 7 TAB, SOLDER LUG INPUT 1ST FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 8 TAB, SOLDER LUG OUTPUT 2ND FUNCTION |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 230.00 HERTZ 1ST BAND PASS 1ST FUNCTION AND 250.00 HERTZ 1ST BAND PASS 1ST FUNCTION AND 270.00 HERTZ 1ST BAND PASS 1ST FUNCTION AND 290.00 HERTZ 1ST BAND PASS 1ST FUNCTION |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 240.00 HERTZ 2ND BAND PASS 2ND FUNCTION AND 260.00 HERTZ 2ND BAND PASS 2ND FUNCTION AND 280.00 HERTZ 2ND BAND PASS 2ND FUNCTION AND 300.00 HERTZ 2ND BAND PASS 2ND FUNCTION |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 250.00 HERTZ 3RD BAND PASS 3RD FUNCTION AND 270.00 HERTZ 3RD BAND PASS 3RD FUNCTION AND 290.00 HERTZ 3RD BAND PASS 3RD FUNCTION AND 310.00 HERTZ 3RD BAND PASS 3RD FUNCTION |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 260.00 HERTZ 4TH BAND PASS 4TH FUNCTION AND 280.00 HERTZ 4TH BAND PASS 4TH FUNCTION AND 300.00 HERTZ 4TH BAND PASS 4TH FUNCTION AND 320.00 HERTZ 4TH BAND PASS 4TH FUNCTION |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 270.00 HERTZ 5TH BAND PASS 5TH FUNCTION AND 290.00 HERTZ 5TH BAND PASS 5TH FUNCTION AND 310.00 HERTZ 5TH BAND PASS 5TH FUNCTION AND 330.00 HERTZ 5TH BAND PASS 5TH FUNCTION |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 280.00 HERTZ 6TH BAND PASS 6TH FUNCTION AND 300.00 HERTZ 6TH BAND PASS 6TH FUNCTION AND 320.00 HERTZ 6TH BAND PASS 6TH FUNCTION AND 340.00 HERTZ 6TH BAND PASS 6TH FUNCTION |
CQJX | NOMINAL THREAD SIZE | 0.375 INCHES |
CQRG | BODY MATERIAL | METAL |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 250.00 HERTZ 1ST BAND PASS AND 270.00 HERTZ 1ST BAND PASS |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 260.00 HERTZ 2ND BAND PASS AND 280.00 HERTZ 2ND BAND PASS |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 270.00 HERTZ 3RD BAND PASS AND 290.00 HERTZ 3RD BAND PASS |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 280.00 HERTZ 4TH BAND PASS AND 300.00 HERTZ 4TH BAND PASS |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 290.00 HERTZ 5TH BAND PASS AND 310.00 HERTZ 5TH BAND PASS |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 300.00 HERTZ 6TH BAND PASS AND 320.00 HERTZ 6TH BAND PASS |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 20.0 MINIMUM 1ST BAND PASS 1ST FUNCTION AND 3.0 MAXIMUM 1ST BAND PASS 1ST FUNCTION AND 3.0 MAXIMUM 1ST BAND PASS 1ST FUNCTION AND 20.0 MINIMUM 1ST BAND PASS 1ST FUNCTION |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 20.0 MINIMUM 2ND BAND PASS 2ND FUNCTION AND 3.0 MAXIMUM 2ND BAND PASS 2ND FUNCTION AND 3.0 MAXIMUM 2ND BAND PASS 2ND FUNCTION AND 20.0 MINIMUM 2ND BAND PASS 2ND FUNCTION |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 20.0 MINIMUM 3RD BAND PASS 3RD FUNCTION AND 3.0 MAXIMUM 3RD BAND PASS 3RD FUNCTION AND 3.0 MAXIMUM 3RD BAND PASS 3RD FUNCTION AND 20.0 MINIMUM 3RD BAND PASS 3RD FUNCTION |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 20.0 MINIMUM 4TH BAND PASS 4TH FUNCTION AND 3.0 MAXIMUM 4TH BAND PASS 4TH FUNCTION AND 3.0 MAXIMUM 4TH BAND PASS 4TH FUNCTION AND 20.0 MINIMUM 4TH BAND PASS 4TH FUNCTION |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 20.0 MINIMUM 5TH BAND PASS 5TH FUNCTION AND 3.0 MAXIMUM 5TH BAND PASS 5TH FUNCTION AND 3.0 MAXIMUM 5TH BAND PASS 5TH FUNCTION AND 20.0 MINIMUM 5TH BAND PASS 5TH FUNCTION |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 20.0 MINIMUM 6TH BAND PASS 6TH FUNCTION AND 3.0 MAXIMUM 6TH BAND PASS 6TH FUNCTION AND 3.0 MAXIMUM 6TH BAND PASS 6TH FUNCTION AND 20.0 MINIMUM 6TH BAND PASS 6TH FUNCTION |
FEAT | SPECIAL FEATURES | 15 FUNCTIONS |
PKWT | UNPACKAGED UNIT WEIGHT | 20.000 POUNDS |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |
20-0-000B1-20 | 20-0-120 | 20-0-120 | 20-0-000B |
20.0-8GROOVE-8V | 20-0-000B | 20-0-144 | 20-0-144 |
20.00-20 | 20-0-000B | 20.00-20 | 20-0-144 |
20-0-144 | 20-0-000B2 | 20-0-120 | 20.00-20 26 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote