Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5915-00-836-6259 Item Description: Filter Band Pass | 5915 | 008366259 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
20-0787-00 | 2 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABKW | OVERALL HEIGHT | 1.500 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 0.750 INCHES MAXIMUM |
ADAT | BODY WIDTH | 0.750 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 0.750 INCHES MAXIMUM |
AECR | VIBRATION RESISTANCE RANGE IN HERTZ | +10.0/+55.0 |
AFGA | OPERATING TEMP RANGE | -55.0/+85.0 DEG CELSIUS |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 10.0 KILOHERTZ BLANK |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 30.0 KILOHMS BLANK |
AHAS | LOAD IMPEDANCE PER FUNCTION | 500.0 OHMS BLANK |
AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 4.0 KILOHMS BLANK |
AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 4.0 KILOHMS BLANK |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 TERMINAL |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 2.0 BLANK |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD INPUT 1ST FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD OUTPUT 2ND FUNCTION |
CQRG | BODY MATERIAL | PLASTIC |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |
TEST | TEST DATA DOCUMENT | 65597-38912-1 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAW |
AKNA | INCLOSURE TYPE | ENCAPSULATED |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 30.00 HERTZ BLANK AND 9.50 KILOHERTZ BLANK AND 10.50 KILOHERTZ BLANK AND 20.00 KILOHERTZ BLANK |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 9.50 KILOHERTZ BLANK AND 10.50 KILOHERTZ BLANK |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 30.0 MINIMUM BLANK AND 1.5 MAXIMUM BLANK AND 1.5 MAXIMUM BLANK AND 28.0 MINIMUM BLANK |
CRDC | MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 100.0 VOLTS AT SEA LEVEL |
20-0-144 | 20.00-20 26 | 20-0-000B | 20-0-000B |
20-0-120 | 20.00-20 | 20.00-20 | 20-0-120 |
20-0-144 | 20-0-144 | 20-0-120 | 20.00-20 26 |
20-0-144HTD | 20.00-20 | 20-0-000B | 20-0-000B1-20 |