Note : We Will Not Share Your Information To Any Third Parties.
MRC | Criteria | Characteristic |
---|---|---|
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
APCN | COIL QUANTITY | 1 |
AAJF | THREAD DIRECTION | RIGHT-HAND SINGLE MOUNTING FACILITY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
SR-1 | NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MIL-R-5757/13 |
APNA | WINDING DC RESISTANCE RATING | 5.0 KILOHMS NOMINAL SINGLE WINDING |
AKDX | WINDING QUANTITY | 1 |
CBME | III CUBIC MEASURE | 0.852 CUBIC INCHES |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
ABKW | OVERALL HEIGHT | 0.817 INCHES MAXIMUM |
SR-1 | SPEC/STD CONTROLLING DATA | |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 6.0 MILLIAMPERES DC SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 300.0 MILLIAMPERES AC AND 2.0 AMPERES DC RESISTIVE LOAD 750.0 MILLIAMPERES DC INDUCTIVE LOAD 100.0 MILLIAMPERES DC LAMP LOAD |
APNP | DUTY TYPE | CONTINUOUS |
APNQ | ARC QUENCHING METHOD | AIR |
AFJN | III FRAGILITY FACTOR | MODERATELY RUGGED |
AKSL | III PURPOSE FOR WHICH DESIGNED | GENERAL |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-5757/13 GOVERNMENT SPECIFICATION |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED STUD SINGLE MOUNTING FACILITY |
CMLP | THREAD QUANTITY PER INCH | 40 SINGLE MOUNTING FACILITY |
ADTV | III CASE MATERIAL | METAL |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES SINGLE MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | DIAGONAL SINGLE MOUNTING FACILITY |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
AAJD | THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
ABHP | OVERALL LENGTH | 1.281 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.805 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CRXH | TIME DELAY | 0.015 SECONDS MAXIMUM FIXED OPERATE TIME 0.01 SECONDS MAXIMUM FIXED RELEASE TIME |
SR-1 | MANUFACTURERS CODE | 81349 |
ABMK | OVERALL WIDTH | 0.815 INCHES MAXIMUM |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.225 INCHES NOMINAL SINGLE MOUNTING FACILITY |
BBRG | III STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
SR-1 | DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | M5757/13-068 |
TTQY | TERMINAL TYPE AND QUANTITY | 8 WIRE LEAD ALL FUNCTIONS |
2BC-1931 | 2BC-1510-50 | 2BC-1664 | 2BC-1510-75 |
2BC-1931 | 2BC-1510-19 | 2BC-1510-75 | 2BC-1931 |
2BC-18 | 2BC-1510-50 | 2BC-1897 | 2BC-1897 |
2BC-1510-19 | 2BC 1510 51 | 2BC-1510-51 | 2BC-1510-50 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote